Effects of inserting a pressensor film into articular joints on the actual contact mechanics

被引:99
作者
Wu, JZ
Herzog, W [1 ]
Epstein, M
机构
[1] Univ Calgary, Fac Kinesiol, Human Performance Lab, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Fac Engn, Dept Mech Engn, Calgary, AB T2N 1N4, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1998年 / 120卷 / 05期
关键词
D O I
10.1115/1.2834758
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Fuji film has been widely used in studies aimed at obtaining the contact mechanics of articular joints. Once sealed for practical use in biological joints, Fuji Pressensor film has a total effective thickness of 0.30 mm, which is comparable to the cartilage thickness in the joints of many small animals. The average effective elastic modulus of Fuji film is approximately 100 MPa in compression, which is larger by a factor of 100-300 compared to that of normal articular cartilage. Therefore, inserting a Pressensor film into an articular joint will change the contact mechanics of the joint. The measurement precision of the Pressensor film has been determined systematically, however, the changes in contact mechanics associated with inserting the film into joints have not been investigated. This study was aimed at quantifying the changes in the contact mechanics associated with inserting seated Fuji Pressensor film into joints. Spherical and cylindrical articular joint contact mechanics with and without Pressensor film and for varying degrees of surface congruency were analyzed and compared by using finite element models. The Pressensor film was taken as linearly elastic and the cartilage was assumed to be biphasic, composed of a linear elastic solid phase and an inviscid fluid phase. The present analyses showed that measurements of the joint contact pressures with Fuji Pressensor film will change the maximum true contact pressures by 10-26 percent depending on the loading, geometry of the joints, and the mechanical properties of cartilage. Considering this effect plus the measurement precision of the film (approximately 10 percent), the measured joint contact pressures in a joint may contain errors as large as 14-28 percent.
引用
收藏
页码:655 / 659
页数:5
相关论文
共 15 条
[1]
INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE [J].
ATHANASIOU, KA ;
ROSENWASSER, MP ;
BUCKWALTER, JA ;
MALININ, TI ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) :330-340
[2]
CONTACT STRESS ABERRATIONS FOLLOWING IMPRECISE REDUCTION OF SIMPLE TIBIAL PLATEAU FRACTURES [J].
BROWN, TD ;
ANDERSON, DD ;
NEPOLA, JV ;
SINGERMAN, RJ ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (06) :851-862
[3]
*FUJI FILM CORP, 1990, FUJ PRESS FILM INSTR
[4]
THE CONTACT AREA AND PRESSURE DISTRIBUTION PATTERN OF THE KNEE - A STUDY OF NORMAL AND OSTEOARTHROTIC KNEE JOINTS [J].
FUKUBAYASHI, T ;
KUROSAWA, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (06) :871-879
[5]
CONTACT STRESS GRADIENT DETECTION LIMITS OF PRESSENSOR FILM [J].
HALE, JE ;
BROWN, TD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03) :352-357
[6]
*HKS, 1996, ABAQUS MAN VERS 5 5
[7]
CONTACT PRESSURES IN CHONDROMALACIA PATELLAE AND THE EFFECTS OF CAPSULAR RECONSTRUCTIVE PROCEDURES [J].
HUBERTI, HH ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (04) :499-508
[8]
An analytical model to study blunt impact response of the rabbit P-F joint [J].
Li, XW ;
Haut, RC ;
Altiero, NJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04) :485-491
[9]
THE SPATIAL AND PRESSURE RESOLUTION OF FUJI PRESSURE-SENSITIVE FILM [J].
LIGGINS, AB ;
HARDIE, WR ;
FINLAY, JB .
EXPERIMENTAL MECHANICS, 1995, 35 (02) :166-173
[10]
LIGGINS AB, 1995, MED ENG PHYS, V6, P496