Biosensor for the specific detection of a single viable B-anthracis spore

被引:53
作者
Hartley, HA [1 ]
Baeumner, AJ [1 ]
机构
[1] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
关键词
biosensor; B; anthracis; RNA; detection; spore; viable; biosecurity;
D O I
10.1007/s00216-003-1939-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple membrane strip-based biosensor for the detection of viable B. anthracis spores was developed and combined with a spore germination procedure as well as a nucleic acid amplification reaction to identify as little as one viable B. anthracis spore in less than 12 h. The biosensor is based on identification of a unique mRNA sequence from the anthrax toxin activator (atxA) gene encoded on the toxin plasmid, pXO1. Preliminary work relied on plasmid vectors in both E. coli and B. thuringiensis expressing the atxA gene. Once the principle was firmly established, the vaccine strain of B. anthracis was used. After inducing germination and outgrowth of spores of B. anthracis (Sterne strain), RNA was extracted from lysed cells, amplified using nucleic acid sequence based amplification (NASBA), and rapidly identified by the biosensor. While the biosensor assay requires only 15-min assay time, the overall process takes 12 h for the detection of as little as one viable B. anthracis spore, and is shortened significantly, if larger amounts of spores are present. The biosensor is based on an oligonucleotide sandwich-hybridization assay format. It uses a membrane flow-through system with an immobilized oligonucleotide probe that hybridizes with the target sequence. Signal amplification is provided when the target sequence hybridizes to a second oligonucleotide probe that has been coupled to dye-encapsulating liposomes. The dye in the liposomes then provides a signal that can be read visually or quantified with a hand-held reflectometer. The biosensor can detect as little as 1.5 fmol of target mRNA. Specificity analysis revealed no crossreactivity with closely related species such as B. cereus, B. megaterium, B. subtilis, B. thuringiensis etc.
引用
收藏
页码:319 / 327
页数:9
相关论文
共 44 条
[1]   AGAR DIFFUSION METHOD FOR DIFFERENTIATION OF BACILLUS-ANTHRACIS [J].
ANGELETY, LH ;
WRIGHT, GG .
APPLIED MICROBIOLOGY, 1971, 21 (01) :157-&
[2]   RNA biosensor for the rapid detection of viable Escherichia coli in drinking water [J].
Baeumner, AJ ;
Cohen, RN ;
Miksic, V ;
Min, JH .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :405-413
[3]   Biosensor for Dengue virus detection: Sensitive, rapid, and serotype specific [J].
Baeumner, AJ ;
Schlesinger, NA ;
Slutzki, NS ;
Romano, J ;
Lee, EM ;
Montagna, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1442-1448
[4]  
BELTON FC, 1954, BRIT J EXP PATHOL, V35, P144
[5]  
Beverly MB, 1999, RAPID COMMUN MASS SP, V13, P2320, DOI 10.1002/(SICI)1097-0231(19991215)13:23<2320::AID-RCM791>3.0.CO
[6]  
2-Q
[7]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[8]   DETECTION OF SPORES OF BACILLUS-ANTHRACIS USING THE POLYMERASE CHAIN-REACTION [J].
CARL, M ;
HAWKINS, R ;
COULSON, N ;
LOWE, J ;
ROBERTSON, DL ;
NELSON, WM ;
TITBALL, RW ;
WOODY, JN .
JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (06) :1145-1148
[9]   Ultrasensitive, direct detection of a specific DNA sequence of Bacillus anthracis in solution [J].
Castro, A ;
Okinaka, RT .
ANALYST, 2000, 125 (01) :9-11
[10]  
COGNE R, 1996, SALISBURY MED B S, V87, P34