Internal standardization in graphite furnace atomic absorption spectrometry:: Comparative use of As and Ge to minimize matrix effects on Se determination in milk

被引:12
作者
de Oliveira, AP
Neto, JAG
Nóbrega, JA
Oliveira, PV
机构
[1] Univ Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, SP, Brazil
关键词
milk; internal standardization; GFAAS; selenium;
D O I
10.1016/j.sab.2005.02.005
中图分类号
O433 [光谱学];
学科分类号
0703 [化学]; 070302 [分析化学];
摘要
Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with I'd as chemical modifier. The efficiency of As and Ge as internal standards for 25 mu g L-1 Se plus 500 mu g (L)-1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis gamma) versus analyte (axis x). The equations that describe the linear regression were: A(As)= - 0.004 +/- 0.019 +/- 1.02 + 0.019 A(Se) (r=0.9967 +/- 0.005); A(Ge)= - 0.0 17 +/- 0.015 + 1.01 +/- 0.015 A(Se) (r = 0.9978 +/- 0.004). Samples and reference solutions were automatically spiked with 500 mu g L-1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 mu L of aqueous standard solutions, analytical curves in the 5.00-40.0 mu g L-1 Se range were established using the ratio of Se absorbance to internal standard absorbance (A(Se)A(IS)) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 mu g L-1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 mu g L-1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99-105% range with IS and in the 70-80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 mu g L-1. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:681 / 686
页数:6
相关论文
共 15 条
[1]
Direct determination of selenium in coconut water and coconut milk using graphite furnace atomic absorption spectrometry. [J].
Aleixo, PC ;
Nóbrega, JA ;
Santos, D ;
Muller, PCS .
QUIMICA NOVA, 2000, 23 (03) :310-312
[2]
Direct determination of iron and selenium in bovine milk by graphite furnace atomic absorption spectrometry [J].
Aleixo, PC ;
Nóbrega, JA .
FOOD CHEMISTRY, 2003, 83 (03) :457-462
[3]
ALEJOS MS, 2002, NUTRITION, V16, P376
[4]
BUTCHER DJ, 1998, PRACTICAL GUID GRAPH
[5]
Silver as internal standard for simultaneous determination of Cd and Pb in whole blood by electrothermal atomic absorption spectrometry [J].
Correia, PRM ;
Oliveira, PV ;
Neto, JAG ;
Nóbrega, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) :917-922
[6]
The distribution of Selenium and mortality owing to acquired immune deficiency syndrome in the continental United States [J].
Cowgill, UM .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1997, 56 (01) :43-61
[7]
Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry [J].
Fernandes, KG ;
de Moraes, M ;
Neto, JAG ;
Nóbrega, JA ;
Oliveira, PV .
ANALYST, 2002, 127 (01) :157-162
[8]
Kim J, 1998, J FOOD SCI, V63, P629
[9]
Evaluation of tungsten-rhodium coating on an integrated platform as a permanent chemical modifier for cadmium, lead, and selenium determination by electrothermal atomic absorption spectrometry [J].
Lima, EC ;
Krug, FJ ;
Jackson, KW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (13) :1791-1804
[10]
REAL-TIME INTERNAL STANDARDIZATION FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY USING A CUSTOM SEGMENTED-ARRAY CHARGE-COUPLED-DEVICE DETECTOR [J].
MERMET, JM ;
IVALDI, JC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :795-801