Differences in observer variability of ultrasound measurements of the proximal and distal abdominal aorta

被引:34
作者
Pleumeekers, HJCM
Hoes, AW
Mulder, PGH
van der Does, E
Hofman, A
Lameris, JS
Grobbee, DE
机构
[1] Erasmus Univ, Sch Med, Dept Gen Practice, NL-3000 DR Rotterdam, Netherlands
[2] Erasmus Univ, Dept Epidemiol & Biostat, NL-3000 DR Rotterdam, Netherlands
[3] Univ Utrecht, Julius Ctr Patient Oriented Res, Utrecht, Netherlands
关键词
aneurysms; abdominal aorta; elderly;
D O I
10.1136/jms.5.2.104
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
Objective-To assess the observer variability of ultrasound measurements of the abdominal aorta and to study whether observer variability is influenced by the site of measurement or cardiovascular risk factors. Setting-Population based screening programme for abdominal aortic aneurysms. Methods-For 135 subjects taking part in a screening programme for abdominal aortic aneurysms, two of the three ultrasonographers measured the distal and proximal ultrasound diameter of the abdominal aorta, using B-mode ultrasound, according to the Rotterdam study scanning protocol. Results-The mean difference between two different observers was 0.06 mm (95% CI -0.15 to 0.27) for measurements of the distal aorta and 0.32 mm (95% CI 0.09 to 0.55) for the proximal aorta. Maximal differences between observers for measurements of both the distal and proximal aortic diameter were 4.0 mm. Interobserver variability in the proximal and distal measurements of the abdominal aorta was not related to the level of the major cardiovascular risk indicators. However, interobserver variability in ultrasound measurements of the proximal aorta increased with increasing waist circumference and increasing diameter of the proximal aorta. Conclusion-Ultrasonographic readings of the distal and proximal aortic measurements can be interpreted within a range of plus or minus 3 mm. Ultrasound measurements are more accurate for the distal than for the proximal measurement. Definition of the aortic diameter based on a combination of both distal and proximal measurement may be more accurate.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 21 条
[1]
AKKERSDIJK GJM, 1994, BRIT J SURG, V81, P372
[2]
Armitage P., 1971, STAT METHODS MED RES
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
STATISTICAL-METHODS FOR ASSESSING OBSERVER VARIABILITY IN CLINICAL MEASURES [J].
BRENNAN, P ;
SILMAN, A .
BMJ-BRITISH MEDICAL JOURNAL, 1992, 304 (6840) :1491-1494
[5]
ABDOMINAL AORTIC-ANEURYSMS IN WESTERN AUSTRALIA - DESCRIPTIVE EPIDEMIOLOGY AND PATTERNS OF RUPTURE [J].
CASTLEDEN, WM ;
MERCER, JC .
BRITISH JOURNAL OF SURGERY, 1985, 72 (02) :109-112
[6]
LIMITATIONS OF ULTRASONOGRAPHY IN SURVEILLANCE OF SMALL ABDOMINAL AORTIC-ANEURYSMS [J].
ELLIS, M ;
POWELL, JT ;
GREENHALGH, RM .
BRITISH JOURNAL OF SURGERY, 1991, 78 (05) :614-616
[7]
INFRARENAL ABDOMINAL AORTIC-ANEURYSMS LESS THAN 5 CENTIMETERS IN DIAMETER - THE SURGEONS DILEMMA [J].
GEROULAKOS, G ;
NICOLAIDES, A .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (06) :616-622
[8]
A STATISTICAL-ANALYSIS OF THE GROWTH OF SMALL ABDOMINAL AORTIC-ANEURYSMS [J].
GRIMSHAW, GM ;
THOMPSON, JM ;
HAMER, JD .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (06) :741-746
[9]
REDUCING THE MORTALITY FROM ABDOMINAL AORTIC-ANEURYSMS - NEED FOR A NATIONAL SCREENING-PROGRAM [J].
HARRIS, PL .
BMJ-BRITISH MEDICAL JOURNAL, 1992, 305 (6855) :697-699
[10]
DETERMINANTS OF DISEASE AND DISABILITY IN THE ELDERLY - THE ROTTERDAM ELDERLY STUDY [J].
HOFMAN, A ;
GROBBEE, DE ;
DEJONG, PTVM ;
VANDENOUWELAND, FA .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 1991, 7 (04) :403-422