Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

被引:9
作者
Bartlett, ML [1 ]
Seaton, D [1 ]
McEwan, L [1 ]
Fong, W [1 ]
机构
[1] Univ Queensland, Royal Brisbane Hosp, Dept Nucl Med, Herston, Qld 4029, Australia
关键词
right ventricle; ejection fraction; nuclear medicine; tomography; ventricular function;
D O I
10.1007/s002590100503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels "greyed out". This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively).
引用
收藏
页码:608 / 613
页数:6
相关论文
共 14 条
[1]  
Bartlett ML, 1996, J NUCL MED, V37, P1795
[2]  
Chin BB, 1997, J NUCL MED, V38, P942
[3]   Right ventricular ejection fraction is an independent predictor of survival in patients with moderate heart failure [J].
de Groote, P ;
Millaire, A ;
Foucher-Hossein, C ;
Nugue, O ;
Marchandise, X ;
Ducloux, G ;
Lablanche, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) :948-954
[4]   PRESERVED RIGHT-VENTRICULAR EJECTION FRACTION PREDICTS EXERCISE CAPACITY AND SURVIVAL IN ADVANCED HEART-FAILURE [J].
DISALVO, TG ;
MATHIER, M ;
SEMIGRAN, MJ ;
DEC, GW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (05) :1143-1153
[5]   QUANTIFICATION OF RIGHT-VENTRICULAR FUNCTION WITH MAGNETIC-RESONANCE-IMAGING IN CHILDREN WITH NORMAL HEARTS AND WITH CONGENITAL HEART-DISEASE [J].
HELBING, WA ;
REBERGEN, SA ;
MALIEPAARD, C ;
HANSEN, B ;
OTTENKAMP, J ;
REIBER, JHC ;
DEROOS, A .
AMERICAN HEART JOURNAL, 1995, 130 (04) :828-837
[6]   OPTIMIZING THE METHOD TO CALCULATE RIGHT-VENTRICULAR EJECTION FRACTION FROM FIRST-PASS DATA ACQUIRED WITH A MULTICRYSTAL CAMERA [J].
JOHNSON, LL ;
LAWSON, MA ;
BLACKWELL, GG ;
TAUXE, EL ;
RUSSELL, K ;
DELLITALIA, LJ .
JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (05) :372-379
[7]   SOURCES OF VARIABILITY IN THE RADIONUCLIDE ANGIOGRAPHIC ASSESSMENT OF EJECTION FRACTION - A COMPARISON OF 1ST-PASS AND GATED EQUILIBRIUM TECHNIQUES [J].
KAUL, S ;
BOUCHER, CA ;
OKADA, RD ;
NEWELL, JB ;
STRAUSS, HW ;
POHOST, GM .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) :823-828
[8]   Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds: application to the determination of right and left ejection fractions [J].
Mariano-Goulart, D ;
Collet, H ;
Kotzki, PO ;
Zanca, M ;
Rossi, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (09) :1300-1307
[9]  
NICHOLS K, 1994, J NUCL MED, V35, P1292
[10]   REPRODUCIBILITY OF MRI-DERIVED MEASUREMENTS OF RIGHT-VENTRICULAR VOLUMES AND MYOCARDIAL MASS [J].
PATTYNAMA, PMT ;
LAMB, HJ ;
VANDERVELDE, EA ;
VANDERGEEST, RJ ;
VANDERWALL, EE ;
DEROOS, A .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :53-63