Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure

被引:28
作者
Kawaguchi, O
Pae, WE
Daily, BB
Pierce, WS
机构
[1] Penn State Univ, Milton S Hershey Med Ctr, Off Surg Res, Dept Surg,Div Cardiothorac Surg,Coll Med, Hershey, PA 17033 USA
[2] Jewish Hosp, Dept Surg, St Louis, MO USA
关键词
D O I
10.1016/S0022-5223(99)70482-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We analyzed the mechanism of effects of intra-aortic balloon pumping using the pressure-volume relationship and ventriculoarterial coupling in the normal and failing hearts. Materials: In 12 anesthetized Holstein calves ( weight, 93 +/- 8 kg), the ventricular end-systolic and arterial elastances, pressure-volume area, and external work were analyzed during steady-state contractions with traditional hemodynamic parameters with intra-aortic balloon pumping-off and -on (1:1 synchronous ratio). An acute ischemic heart failure was induced by injecting 10 mu m microspheres (4.2 +/- 1.8 x 10(7 .)100g left ventricular weight(-1)) into the left main coronary artery; all measurements were repeated, Results: Intraaortic balloon pumping did not change hemodynamic parameters in the control. However, during heart failure, intra-aortic balloon pumping decreased the arterial elastance from 3.6 +/- 3.3 mm Hg to 2.9 +/- 1.2 mm Hg . mL(-1) while not affecting the ventricular end-systolic elastance, this resulted in an improvement of the ventriculoarterial coupling ratio from 3.1 +/- 0.8 to 2.3 +/- 0.8, Intra-aortic balloon pumping decreased not only end-systolic pressure (from 69 +/- 16 mm Hg to 64 +/- 19 mm Hg) but end-diastolic volume and pressure (from 139 +/- 38 mt to 137 +/- 37 mt and from 13.9 mm Hg to 12.8 mm Hg, respectively) with the leftward shift of the pressure-volume loop. Pressure-volume area decreased (from 914 +/- 284 mm Hg to 849 +/- 278 mm Hg mt) although stroke volume increased (from 21 +/- 6 mt to 24 +/- 6 mL). Conclusion: Reduction of the arterial elastance with intra-aortic balloon pumping improved the ventriculoarterial coupling ratio and increased stroke volume. Leftward shift of the pressure-volume loop resulted in the reduction of pressure-volume area, which suggests the conservation of the myocardial oxygen consumption.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 26 条
[1]   VENTRICULOARTERIAL COUPLING IN NORMAL AND FAILING HEART IN HUMANS [J].
ASANOI, H ;
SASAYAMA, S ;
KAMEYAMA, T .
CIRCULATION RESEARCH, 1989, 65 (02) :483-493
[2]   EFFECT OF CIRCULATORY ASSIST DEVICES ON STUNNED MYOCARDIUM [J].
BAVARIA, JE ;
FURUKAWA, S ;
KREINER, G ;
GUPTA, KB ;
STREICHER, J ;
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1990, 49 (01) :123-128
[3]   DIASTOLIC AUGMENTATION BY INTRA-AORTIC BALLOON - CIRCULATORY HEMODYNAMICS AND TREATMENT OF SEVERE ACUTE LEFT VENTRICULAR FAILURE IN DOGS [J].
BROWN, BG ;
GOLDFARB, D ;
TOPAZ, SR ;
GOTT, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1967, 53 (06) :789-&
[4]   ROLE OF OXYGEN-DERIVED FREE-RADICALS IN MYOCARDIAL EDEMA AND ISCHEMIA IN CORONARY MICROVASCULAR EMBOLIZATION [J].
HORI, M ;
GOTOH, K ;
KITAKAZE, M ;
IWAI, K ;
IWAKURA, K ;
SATO, H ;
KORETSUNE, Y ;
INOUE, M ;
KITABATAKE, A ;
KAMADA, T .
CIRCULATION, 1991, 84 (02) :828-840
[5]   VENTRICULAR LOAD OPTIMIZATION BY UNLOADING THERAPY IN PATIENTS WITH HEART-FAILURE [J].
KAMEYAMA, T ;
ASANOI, H ;
ISHIZAKA, S ;
SASAYAMA, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (01) :199-207
[6]   LEFT-VENTRICULAR MECHANOENERGETICS DURING ASYNCHRONOUS LEFT ATRIAL-TO-AORTIC BYPASS - EFFECTS OF PUMPING RATE ON CARDIAC WORKLOAD AND MYOCARDIAL OXYGEN-CONSUMPTION [J].
KAWAGUCHI, O ;
PAE, WE ;
DAILY, WB ;
SAPIRSTEIN, JS ;
PIERCE, WS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03) :793-799
[7]   LEFT-VENTRICULAR MECHANICS DURING SYNCHRONOUS LEFT ATRIAL-AORTIC BYPASS [J].
KAWAGUCHI, O ;
SAPIRSTEIN, JS ;
DAILY, WB ;
PAE, WE ;
PIERCE, WS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (06) :1503-1511
[8]   Arterial impedance in patients during intraaortic balloon counterpulsation [J].
Kim, SY ;
Euler, DE ;
Jacobs, WR ;
Montoya, A ;
Sullivan, HJ ;
Lonchyna, VA ;
Pifarre, R .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :888-893
[9]   DYNAMIC EFFECTS OF CAROTID-SINUS BAROREFLEX ON VENTRICULOARTERIAL COUPLING STUDIED IN ANESTHETIZED DOGS [J].
KUBOTA, T ;
ALEXANDER, J ;
ITAYA, R ;
TODAKA, K ;
SUGIMACHI, M ;
SUNAGAWA, K ;
NOSE, Y ;
TAKESHITA, A .
CIRCULATION RESEARCH, 1992, 70 (05) :1044-1053
[10]   EFFECT OF REGIONAL ISCHEMIA ON THE LEFT-VENTRICULAR END-SYSTOLIC PRESSURE-VOLUME RELATION IN CHRONICALLY INSTRUMENTED DOGS [J].
LITTLE, WC ;
OROURKE, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) :297-302