Applicability of a scale-up methodology for wet granulation processes in Collette Gral high shear mixer-granulators

被引:41
作者
Faure, A
Grimsey, IM
Rowe, RC
York, P [1 ]
Cliff, MJ
机构
[1] Univ Bradford, Sch Pharm, Drug Delivery Grp, Postgrad Studies Pharmaceut Studies, Bradford BD7 1DP, W Yorkshire, England
[2] Zeneca Pharmaceut, Macclesfield, Cheshire, England
关键词
wet granulation; scale-up; mixer-granulator; wall adhesion; wet mass consistency;
D O I
10.1016/S0928-0987(98)00063-3
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study investigates the extension of a scale-up methodology based on dimensionless power relationships, to a series of vertical mixer-granulators in which the bowl is removable, i.e. both impeller and chopper blades are mounted on top-driven vertical shafts positioned through the lid. Granulation runs were carried out in several bowl sizes belonging to the series of Collette Gral mixer-granulators, ranging from 8 to 6001 capacities. It was shown that under certain conditions a common scale-up master curve could be drawn from the data gathered for each bowl, thus permitting the use of such a curve for the determination of mixer-granulator power consumption at a defined granulation end-point. The results also helped to clarify the concept of similitude, both geometrical and dynamic, which is implied in the methodology. The importance of wall slippage (as promoted by the insertion of a PTFE lining into the bowls) and batch size are illustrated. (C) 1999 Elsevier Science BN. All rights reserved.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 15 条
[1]  
CLIFF MJ, 1990, P 12 INT C ADV PUBL
[2]  
EARLE RL, 1983, UNIT OPERATIONS FOOD, P170
[3]  
EDWARDS MF, 1992, MIXING PROCESS IND, pCH8
[4]  
Faure A, 1998, Pharm Dev Technol, V3, P413, DOI 10.3109/10837459809009869
[5]  
HOLLAND FA, 1966, LIQUID MIXING PROCES, P29
[7]   GRANULATION IN HIGH-SPEED MIXERS .6. EFFECTS OF PROCESS CONDITIONS ON POWER-CONSUMPTION AND GRANULE GROWTH [J].
HOLM, P ;
SCHAEFER, T ;
KRISTENSEN, HG .
POWDER TECHNOLOGY, 1985, 43 (03) :225-233
[8]  
HOLM P, 1993, STP PHARMA SCI, V3, P286
[9]   The effect of batch size on scale-up of a pharmaceutical granulation in a fixed bowl mixer granulator [J].
Landin, M ;
York, P ;
Cliff, MJ ;
Rowe, RC ;
Wigmore, AJ .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 134 (1-2) :243-246
[10]   Scale-up of a pharmaceutical granulation in fixed bowl mixer-granulators [J].
Landin, M ;
York, P ;
Cliff, MJ ;
Rowe, RC ;
Wigmore, AJ .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 133 (1-2) :127-131