Imaging brain function in humans at 7 Tesla

被引:346
作者
Yacoub, E
Shmuel, A
Pfeuffer, J
Van de Moortele, PF
Adriany, G
Andersen, P
Vaughan, JT
Merkle, H
Ugurbil, K
Hu, XP
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
关键词
cerebral function; functional imaging; MRI; fMRI; BOLD; ultrahigh field;
D O I
10.1002/mrm.1080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article describes experimental studies performed to demonstrate the feasibility of BOLD fMRI using echo-planar imaging (EPI) at 7 T and to characterize the BOLD response in humans at this ultrahigh magnetic field, Visual stimulation studies were performed in normal subjects using high-resolution multishot EPI sequences, Changes in R-2* arising from visual stimulation were experimentally determined using fMRI measurements obtained at multiple echo times, The results obtained at 7 T were compared to those at 4 T, Experimental data indicate that fMRI can be reliably performed at 7 T and that at this field strength both the sensitivity and spatial specificity of the BOLD response are increased. This study suggests that ultrahigh field MR systems are advantageous for functional mapping in humans. Magn Reson Med 45:588-594, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 42 条
[1]  
ADRIANY G, 2000, P 8 ANN M ISMRM DENV
[2]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[3]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[4]  
BISWAL B, 1994, P 2 C SMR SAN FRANC
[5]   THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO [J].
BOXERMAN, JL ;
BANDETTINI, PA ;
KWONG, KK ;
BAKER, JR ;
DAVIS, TL ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :4-10
[6]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[7]  
Duong TQ, 2000, MAGN RESON MED, V43, P383, DOI 10.1002/(SICI)1522-2594(200003)43:3<383::AID-MRM10>3.0.CO
[8]  
2-Q
[9]   FOCAL PHYSIOLOGICAL UNCOUPLING OF CEREBRAL BLOOD-FLOW AND OXIDATIVE-METABOLISM DURING SOMATOSENSORY STIMULATION IN HUMAN-SUBJECTS [J].
FOX, PT ;
RAICHLE, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (04) :1140-1144
[10]  
Friston K., 1994, HUM BRAIN MAPP, V1, P153, DOI DOI 10.1002/HBM.460010207