Instrumentation, testing and analysis of electric machine rotor steady-state heating

被引:9
作者
Dymond, J [1 ]
Ong, R [1 ]
Stranges, N [1 ]
机构
[1] GE Ind Syst, Peterborough, ON K9J 7B5, Canada
来源
INDUSTRY APPLICATIONS SOCIETY 48TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE | 2001年
关键词
synchronous; induction; rotor; temperature rise; temperature sensors;
D O I
10.1109/PCICON.2001.960579
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
It is not a simple task to measure temperatures on the rotors or rotor components of large induction and synchronous machines during steady state operation. The single greatest obstacle to obtaining this data is related to getting the data from the rotating element. Other problems are associated with instrumentation noise, sensor type and attachment. This paper describes a number of techniques that have been used by the authors and their associates over the last 30 years. Test and calculated temperatures are presented for one machine. Also test data from a number of machines is presented that show for this particular population of enclosures and ventilation schemes the steady state temperatures at the design load can range from the value of the stator rise to greater than 70 degreesC higher.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 4 条
[1]  
*IEC, 1972, 600342 IEC
[2]  
*IEEE, 1121996 IEEE
[3]  
MARTINY WT, 1961, AIEE T APR, P66
[4]  
ROSENBERRY GM, 1955, AIEE T 3 OCT, P819