Atrial activity extraction based on blind source separation as an alternative to QRST cancellation for atrial fibrillation analysis

被引:28
作者
Rieta, JJ [1 ]
Zarzoso, V [1 ]
Millet-Roig, J [1 ]
García-Civera, R [1 ]
Ruiz-Granell, R [1 ]
机构
[1] UPV, EPS Gandia, Dpto Ing Elect, Gandia 46730, Spain
来源
COMPUTERS IN CARDIOLOGY 2000, VOL 27 | 2000年 / 27卷
关键词
D O I
10.1109/CIC.2000.898457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial fibrillation (AF) characterization from electrocardiogram (ECG) recordings requires the elimination of ventricular activity (VA). The present contribution demonstrates the potential of blind source separation (BSS) in atrial activity (AA) extraction from AF episodes. The applicability of BSS techniques relies on the assumption that AA and VA are decoupled, and hence can be regarded as generated by independent bioelectric sources. In the comparative experiments, a multi-lead AF signal model is synthesized by adding real AA from AF episodes to ECGs recorded from healthy patients. Two direct QRST-cancellation methods are also considered: template matching and subtraction, and adaptive noise cancellation. Further experiments are performed on real multi-lead recordings from 20 patients with AF episodes. The BSS approach shows a superior performance, thus manifesting the suitability of BSS techniques for AA extraction. As a favourable by-product, BSS arises as a novel technique for QRST-complex cancellation.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 11 条
[1]  
[Anonymous], 1999, Blind Estimation Using Higher-Order Statistics, DOI DOI 10.1007/978-1-4757-2985-6_4
[2]   Frequency analysis of human atrial fibrillation using the surface electrocardiogram and its response to ibutilide [J].
Bollmann, A ;
Kanuru, NK ;
McTeague, KK ;
Walter, PF ;
DeLurgio, DB ;
Langberg, JJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12) :1439-1445
[3]  
MILLET J, 1997, WORLD C MED PHIS BIO
[4]  
Millet-Roig J, 1998, P ANN INT IEEE EMBS, V20, P1238
[5]   A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236
[6]   Detection of atrial activity from high-voltage leads of implantable ventricular defibrillators using a cancellation technique [J].
Shkurovich, S ;
Sahakian, AV ;
Swiryn, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (02) :229-234
[7]  
SLOCUM J, 1998, IEEE T BIOMED ENG, V45, P229
[8]   Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillation:: Methods and performance [J].
Stridh, M ;
Sörnmo, L .
COMPUTERS IN CARDIOLOGY 1998, VOL 25, 1998, 25 :633-636
[9]  
WIDROW B, 1975, P IEEE, V63, P12
[10]   Blind separation of independent sources for virtually any source probability density function [J].
Zarzoso, V ;
Nandi, AK .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1999, 47 (09) :2419-2432