Examination of the implant-abutment interface after fatigue testing

被引:125
作者
Cibirka, RM
Nelson, SK
Lang, BR
Rueggeberg, FA
机构
[1] Med Coll Georgia, Sch Dent, Dept Oral Rehabil, Augusta, GA 30912 USA
[2] Univ Michigan, Sch Dent, Dept Prosthodont, Ann Arbor, MI 48109 USA
[3] Med Coll Georgia, Sect Dent Mat, Augusta, GA 30912 USA
关键词
D O I
10.1067/mpr.2001.114266
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Purpose. This study examined potential differences in detorque values of abutment screws after fatigue testing when the dimensions between external implant hexagon and internal abutment hexagon were altered or the implant external hexagonal shape was eliminated. Material and methods. Three subsets (N = 10) of NobelBiocare implants were assessed: (1) standard external hexagon (R), (2) modified hexagon (M), and (3) circular (C) platform geometry. Thirty Procera machined abutments with 25-degree angulated loading platforms were manufactured. Abutments were retained with gold Unigrip abutment screws tightened to 32 N/cm with an electronic torque controller. Vertical scribes across the implant-abutment interface allowed longitudinal displacement evaluation. A carousel-type fatigue testing device delivered dynamic loading forces between 20 and 200 N for 5,000,000 cycles, or the approximate equivalent of 5 years in vivo mastication, through a piston to the abutment platform. Macroscopic and radiographic examination of the implant/abutment specimens was performed. The abutment screws were removed and the detorque values recorded. Bearing surfaces were examined microscopically. Results, No abutment looseness or longitudinal displacements at the implant-abutment interface were noted. Radiographic examination demonstrated no indication of screw bending or displacement. The mean detorque values for R, M, and C were 14.40 +/- 1.84 N/cm, 14.70 +/- 1.89 N/cm, and 16.40 +/- 2.17 N/cm, respectively. The analysis of variance demonstrated significant differences between only designs R and C (P=.031). Conclusion. Increasing the vertical height, or degree of fit tolerance, between the implant external hexagon and the abutment internal hexagon or completely eliminating the implant external hexagon did not produce a significant effect on the detorque values of the abutment screws after 5,000,000 cycles in fatigue testing, or the equivalent of 5 years ' of mastication for the implant/abutment specimens evaluated.
引用
收藏
页码:268 / 275
页数:8
相关论文
共 52 条
[1]
Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles [J].
Arvidson, K ;
Bystedt, H ;
Frykholm, A ;
von Konow, L ;
Lothigius, E .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) :225-234
[2]
Arvidson K, 1992, Int J Oral Maxillofac Implants, V7, P321
[3]
Balshi T J, 1990, Quintessence Int, V21, P61
[4]
Balshi T J, 1996, Int J Oral Maxillofac Implants, V11, P372
[5]
REPLACEMENT OF MAXILLARY AND MANDIBULAR MOLARS WITH SINGLE ENDOSSEOUS IMPLANT RESTORATIONS - A RETROSPECTIVE STUDY [J].
BECKER, W ;
BECKER, BE .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (01) :51-55
[6]
Complication rate with prosthodontic reconstructions on ITI and IMZ dental implants [J].
Behr, M ;
Lang, R ;
Leibrock, A ;
Rosentritt, M ;
Handel, G .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (01) :51-58
[7]
Bickford JH, 1981, INTRO DESIGN BEHAV B
[8]
Binon P P, 1996, Implant Dent, V5, P235, DOI 10.1097/00008505-199600540-00002
[9]
Binon P.P., 1994, INT J ORAL MAX SURG, V9, P48
[10]
Binon PP, 1996, INT J PROSTHODONT, V9, P149