Three-phase unbalance of distribution systems: Complementary analysis and experimental case study

被引:84
作者
Bina, M. Tavakoli [1 ]
Kashefi, A. [1 ]
机构
[1] KN Toosi Univ Technol, Fac Elect Engn, Tehran 16314, Iran
关键词
Unbalance; Distribution systems; Substations; Over-capacity; Power losses;
D O I
10.1016/j.ijepes.2010.12.003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three-phase unbalance is a familiar issue for power system researchers and engineers. This can introduce additional power losses in distribution network in steady states due to both negative and zero sequence components. It could also limit the loading capability of distribution transformers, well below their nominal ratings. There are many voltage and current unbalance definitions (e.g.. IEEE and NEMA) for three-phase three-wire systems, assuming zero sequence currents to be of negligible practical value, for they cannot flow in three-wire systems. However, the zero sequence unbalance has significant current magnitude in three-phase with four-wire distribution networks, particularly in developing countries. Hence, this paper concentrates on the distribution unbalance, completing the available definitions in order to maintain tangible relationships between the level of unbalance and the cited consequences in distribution networks. Furthermore, practical works were performed on 11 selected 20 kV/0.4 kV substations within Tehran North-West Distribution System (TNWDS), where data loggers have been installed for 7 days to measure and record operating conditions of substations. Then, detailed analysis and assessment are suggested on empirical data to substantiate the presented complementary definitions and relationships. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:817 / 826
页数:10
相关论文
共 13 条
[1]  
BIMBHRA PS, 1997, ELECT MACHINERY THEO
[2]  
BOLLEN MHJ, 2002, IEEE POWER ENG REV, V1, P49
[3]  
ELWOOD GK, 1974, INTRO STAT PROBABILI
[4]   Influence of unbalanced voltage supply on efficiency of three phase squirrel cage induction motor and economic analysis [J].
Faiz, J ;
Ebrahimpour, H ;
Pillay, P .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (03) :289-302
[5]   Precise derating of three phase induction motors with unbalanced voltages [J].
Faiz, Jawad ;
Ebrahimpour, H. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (09) :2579-2586
[6]  
FORTESCUE CL, 1918, 34 ANN CONV AM I EL, V36, P1027
[7]   Exact voltage unbalance assessment without phase measurements [J].
Ghijselen, JAL ;
Van den Bossche, APM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (01) :519-520
[8]  
Glover J.D., 1994, Power System Analysis and Design
[9]  
*OFF IND TECHN, 2000, 2 US DEP EN OFF IND
[10]   Definitions of voltage unbalance [J].
Pillay, P. ;
Manyage, M. .
IEEE Power Engineering Review, 2001, 21 (05) :50-51