In vitro non-rigid life-size model of aortic arch aneurysm for endovascular prosthesis assessment

被引:70
作者
Sulaiman, Abdurazzaq [1 ]
Boussel, Loic [2 ]
Taconnet, Frederic [3 ]
Serfaty, Jean Michel [2 ]
Alsaid, Hasan [2 ]
Attia, Cherif [1 ]
Huet, Laurent [3 ]
Douek, Philippe [2 ]
机构
[1] Cardiovasc Hosp Louis Pradel, Dept Thorac & Cardiovasc Surg, F-69394 Lyon 03, France
[2] Cardiovasc Hosp Louis Pradel, Dept Cardiovasc Surg, INSERM,U630, CREATIS,UMR 5515, F-69394 Lyon 03, France
[3] SEGULA TECHNOL, F-69800 St Priest, France
关键词
stereolithography; aortic aneurysm; interventional radiology;
D O I
10.1016/j.ejcts.2007.10.016
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Purpose: It is essential to evaluate new stent designs before in vivo testing. The purpose of this study was to develop and validate a controlled and reproducible patient-derived process to produce a life-size in vitro model of aortic arch aneurysm for endovascular procedure simulation. Methods: A three-dimensional magnetic resonance angiography (3D MRA) image derived from a 60-year-old patient with aortic arch aneurysm was segmented using a home-made software package which allows one-click automatic segmentation of the aorta, meshing, and conversion to standard tessellation language (STL) format. A rapid prototyping technique established a stereolithographic model to produce a replica of the whole aorta, including the arch aneurysm and supra-aortic arteries. Results: The final model. was made by pouring silicone rubber to obtain a sturdy, life-size, soft, transparent, plastic cast, accurately reproducing both the internal and external anatomy of the aortic aneurysm. This model was used under perfusion by an extracorporeal circulation pump, to test ex vivo stent deployment. Conclusion: The combination of easy segmentation and conversion to the STL format with industrial stereolithography techniques enabled a realistic silicon vascular phantom to be created for endovascular procedure simulation, image modality calibration, and new stent design. (C) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 26 条
[1]
Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics [J].
Chong, CK ;
Rowe, CS ;
Sivanesan, S ;
Rattray, A ;
Black, RA ;
Shortland, AP ;
How, TV .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) :1-4
[2]
Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial [J].
D'Urso, PS ;
Barker, TM ;
Earwaker, WJ ;
Bruce, LJ ;
Atkinson, RL ;
Lanigan, MW ;
Arvier, JF ;
Effeney, DJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) :30-37
[3]
An opinion survey of reported benefits from the use of stereolithographic models [J].
Erickson, DM ;
Chance, D ;
Schmitt, S ;
Mathis, J .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (09) :1040-1043
[4]
FABRICATION OF VASCULAR REPLICAS FROM MAGNETIC-RESONANCE IMAGES [J].
FRIEDMAN, MH ;
KUBAN, BD ;
SCHMALBROCK, P ;
SMITH, K ;
ALTAN, T .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :364-366
[5]
Gailloud P, 1999, AM J NEURORADIOL, V20, P291
[6]
Computer-assisted analysis of three-dimensional MR angiograms [J].
Hernández-Hoyos, M ;
Orkisz, M ;
Puech, P ;
Mansard-Desbleds, C ;
Douek, P ;
Magnin, IE .
RADIOGRAPHICS, 2002, 22 (02) :421-436
[7]
Imbesi SG, 2001, AM J NEURORADIOL, V22, P721
[8]
Imbesi SG, 1999, AM J NEURORADIOL, V20, P1703
[9]
Karner GERHARD, 1999, Comput Methods Biomech Biomed Engin, V2, P171, DOI 10.1080/10255849908907986
[10]
KERBER CW, 1989, BIORHEOLOGY, V26, P1041