Automatic Detection of Diabetic Retinopathy and Age-Related Macular Degeneration in Digital Fundus Images

被引:71
作者
Agurto, Carla [1 ,2 ]
Barriga, E. Simon [1 ,2 ]
Murray, Victor [1 ]
Nemeth, Sheila [2 ]
Crammer, Robert [2 ,3 ]
Bauman, Wendall [4 ]
Zamora, Gilberto [2 ]
Pattichis, Marios S. [1 ]
Soliz, Peter [2 ,5 ]
机构
[1] Univ New Mexico, Dept Elect & Comp Engn, Albuquerque, NM 87131 USA
[2] VisionQuest Biomed LLC, Albuquerque, NM USA
[3] New Mexico VA Hlth Care Syst, Albuquerque, NM USA
[4] Retinal Inst S Texas, San Antonio, TX USA
[5] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
基金
美国国家卫生研究院;
关键词
PHOTOGRAPHY; EDEMA;
D O I
10.1167/iovs.10-7075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To describe and evaluate the performance of an algorithm that automatically classifies images with pathologic features commonly found in diabetic retinopathy (DR) and age-related macular degeneration (AMD). METHODS. Retinal digital photographs (N = 2247) of three fields of view (FOV) were obtained of the eyes of 822 patients at two centers: The Retina Institute of South Texas (RIST, San Antonio, TX) and The University of Texas Health Science Center San Antonio (UTHSCSA). Ground truth was provided for the presence of pathologic conditions, including microaneurysms, hemorrhages, exudates, neovascularization in the optic disc and elsewhere, drusen, abnormal pigmentation, and geographic atrophy. The algorithm was used to report on the presence or absence of disease. A detection threshold was applied to obtain different values of sensitivity and specificity with respect to ground truth and to construct a receiver operating characteristic (ROC) curve. RESULTS. The system achieved an average area under the ROC curve (AUC) of 0.89 for detection of DR and of 0.92 for detection of sight-threatening DR (STDR). With a fixed specificity of 0.50, the system's sensitivity ranged from 0.92 for all DR cases to 1.00 for clinically significant macular edema (CSME). CONCLUSIONS. A computer-aided algorithm was trained to detect different types of pathologic retinal conditions. The cases of hard exudates within 1 disc diameter (DD) of the fovea (surrogate for CSME) were detected with very high accuracy (sensitivity = 1, specificity = 0.50), whereas mild nonproliferative DR was the most challenging condition (sensitivity = 0.92, specificity = 0.50). The algorithm was also tested on images with signs of AMD, achieving a performance of AUC of 0.84 (sensitivity = 0.94, specificity = 0.50). (Invest Ophthalmol Vis Sci. 2011;52:5862-5871) DOI: 10.1167/iovs.10-7075
引用
收藏
页码:5862 / 5871
页数:10
相关论文
共 24 条
[1]   Automated detection of diabetic retinopathy: barriers to translation into clinical practice [J].
Abramoff, Michael D. ;
Niemeijer, Meindert ;
Russell, Stephen R. .
EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (02) :287-296
[2]   Effects of Image Compression and Degradation on an Automatic Diabetic Retinopathy Screening Algorithm [J].
Agurto, C. ;
Barriga, S. ;
Murray, V. ;
Pattichis, M. ;
Soliz, P. .
MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
[3]  
AGURTO C, 2008, 42 IEEE AS C SIGN SY, P659
[4]   Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection [J].
Agurto, Carla ;
Murray, Victor ;
Barriga, Eduardo ;
Murillo, Sergio ;
Pattichis, Marios ;
Davis, Herbert ;
Russell, Stephen ;
Abramoff, Michael ;
Soliz, Peter .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) :502-512
[5]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P786
[6]  
[Anonymous], IEEE EL POW EN C MON
[7]   AUTOMATIC SYSTEM FOR DIABETIC RETINOPATHY SCREENING BASED ON AM-FM, PARTIAL LEAST SQUARES, AND SUPPORT VECTOR MACHINES [J].
Barriga, E. Simon ;
Murray, Victor ;
Agurto, Carla ;
Pattichis, Marios ;
Bauman, Wendall ;
Zamora, Gilberto ;
Soliz, Peter .
2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, :1349-1352
[8]   AUTOMATED DIAGNOSIS OF RETINOPATHY BY CONTENT-BASED IMAGE RETRIEVAL [J].
Chaum, Edward ;
Karnowski, Thomas P. ;
Govindasamy, V. Priya ;
Abdelrahman, Mohamed ;
Tobin, Kenneth W. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (10) :1463-1477
[9]   Training variability in the evaluation of automated classifiers [J].
Chen, Weijie ;
Gallas, Brandon D. .
MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
[10]   Automated assessment of diabetic retinal image quality based on clarity and field definition [J].
Fleming, AD ;
Philip, S ;
Goatman, KA ;
Olson, JA ;
Sharp, PF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1120-1125