The micro-setup for neutron imaging:: A major step forward to improve the spatial resolution

被引:150
作者
Lehmann, E. H. [1 ]
Frei, G.
Kuehne, G.
Boillat, P.
机构
[1] Paul Scherrer Inst, Spallat Neutron Source Div ASQ, CH-5232 Villigen, Switzerland
[2] Paul Scherrer Inst, Electrochem Lab, CH-5232 Villigen, Switzerland
关键词
neutron imaging; spatial resolution; tomography; scintillator; CCD-camera;
D O I
10.1016/j.nima.2007.03.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
To overcome present limitations of the spatial resolution in neutron imaging a newly designed setup was realized at the ICON facility [G. Kuhne et al., ICON-the new facility for cold neutron imaging at the Swiss spallation neutron source SINQ, Swiss Neutron News 28 (December 2005), pp. 20-29, <http://sgn.web.psi.ch/sgn/snn/snn_28.pdf>], which is installed at the cold neutron beam line 52 at the Swiss spallation neutron source SINQ [G.S. Bauer, Nucl. Instr. and Meth. A 463 (2001) 505] since 2005. It was found by dedicated performance measurements, that the inherent spatial resolution of this locally fixed neutron imaging device is better than 50 mu m, corresponding to 20 line pairs/mm in spatial frequency at 10% of the modulation transfer function (MTF). Therefore, the system has the potential to perform neutron tomography investigations with a resolution better than that previously achieved. This article describes the design features, details of the installation and the results from first test measurements. It gives an outlook for the further potential of this technique in both radiography and tomography applications. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 9 条
[1]
New features in cold neutron radiography and tomography -: Part 1:: thinner scintillators and a neutron velocity selector to improve the spatial resolution [J].
Baechler, S ;
Kardjilov, N ;
Dierick, M ;
Jolie, J ;
Kühne, G ;
Lehmann, E ;
Materna, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (03) :481-491
[3]
BRONNIMANN C, 2004, APPL PILATUS SINGLE
[4]
KARDJILOV N, 2004, THESIS TU MUNICH, P3
[5]
KUHNE G, 2005, SWISS NEUTRON NEWS, V28, P20
[6]
Lehmann EH, 2006, LECT NOTES PHYS, V694, P231, DOI 10.1007/3-540-30272-7_15
[7]
PFEIFFER F, 2006, NEUTRON PHASE IMAG T, V96
[8]
Design of a new CCD-camera neutron radiography detector [J].
Pleinert, H ;
Lehmann, E ;
Korner, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3) :382-390
[9]
UHER J, 2005, NUCL INSTRUM METH A, V542, P319