Megabore versus microbore as the optimal column for fast gas chromatography mass spectrometry

被引:33
作者
Amirav, A [1 ]
Tzanani, N
Wainhaus, SB
Dagan, S
机构
[1] Tel Aviv Univ, Sch Chem, IL-69978 Tel Aviv, Israel
[2] Israel Inst Biol Res, IL-74100 Ness Ziona, Israel
来源
EUROPEAN MASS SPECTROMETRY | 1998年 / 4卷 / 01期
关键词
fast GC/MS; megabore column; GC sample introduction; supersonic molecular beam; MS/MS; pesticide analysis;
D O I
10.1255/ejms.185
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The use of a short megabore (0.53 mm ID) column for fast gas chromatography/mass spectrometry (GC/MS) was compared with the use of a short microbore (0.1 mm ID) capillary column and demonstrated to be superior, Several aspects and experimental parameters that affect fast GC/MS are demonstrated and discussed. These aspects include the acceptable column flow rate, column internal diameter and length, mass analyzer, GC/MS interface properties, ionization method and the inter-relationship between these features. The microbore column provides, at best, a modest gain in chromatographic resolution, however, the accompanying loss in concentration sensitivity is severe due to greatly reduced sample introduction rate and other effects, We claim that, with fast GC/MS analysis the mass spectrometer and ionization methods play a major role in the overall separation capability and that enhanced mass spectrometric separation is more useful than the modest gain achieved with the microbore column, Thus, the use of a supersonic molecular beam with electron ionization or hyperthermal surface ionization contributes greatly to fast GC/MS. This contribution is further enhanced due to the high flow-rate, fast injection that minimizes the time spent on GC temperature programming and cooling. It is demonstrated that fast GC/MS does not necessarily require time-of-flight mass analysis and that the conjectured problem of mass spectral skewing is negligible even with microbore columns. It is emphasized and demonstrated that compatibility with advanced tools for fast sample preparation is an important consideration for an effective fast GC/MS analysis with real-world samples. Fast GC/MS analysis, without extraction, of the pesticide diazinon in the herb chervil is shown using a novel direct sample introduction device, a short megabore column and electron ionization in a supersonic molecular beam.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 29 条
[1]   ELECTRON-IMPACT AND HYPERTHERMAL SURFACE-IONIZATION MASS-SPECTROMETRY IN SUPERSONIC MOLECULAR-BEAMS [J].
AMIRAV, A .
ORGANIC MASS SPECTROMETRY, 1991, 26 (01) :1-17
[2]  
AMIRAV A, 1997, Patent No. 5686656
[3]   VAPOR SAMPLING DEVICE FOR DIRECT SHORT COLUMN GAS-CHROMATOGRAPHY MASS-SPECTROMETRY ANALYSES OF ATMOSPHERIC VAPORS [J].
ARNOLD, NS ;
MCCLENNEN, WH ;
MEUZELAAR, HLC .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :299-304
[4]  
ARTAEV VB, 1994, P 42 ASMS C MASS SPE, P510
[5]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[6]  
Dagan S, 1996, J AM SOC MASS SPECTR, V7, P737, DOI 10.1016/1044-0305(96)80519-8
[7]   FAST, HIGH-TEMPERATURE AND THERMOLABILE GC MS IN SUPERSONIC MOLECULAR-BEAMS [J].
DAGAN, S ;
AMIRAV, A .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 133 (2-3) :187-210
[8]   ELECTRON-IMPACT MASS-SPECTROMETRY OF ALKANES IN SUPERSONIC MOLECULAR-BEAMS [J].
DAGAN, S ;
AMIRAV, A .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (02) :120-131
[9]  
DAGAN S, UNPUB EUR MASS SPECT
[10]  
DAGAN S, 1997, EUR MASS SPECTROM, V3, P105