Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds:: A multicenter study

被引:92
作者
Clarke, M [1 ]
Liu, B
Schüller, H
Binner, L
Kennergren, C
Guerola, M
Weinmann, P
Ohm, OJ
机构
[1] City Gen Hosp, Dept Cardiol, Stoke On Trent ST4 6QG, Staffs, England
[2] Dept Clin Res, Solna, Sweden
[3] Univ Lund, Dept Cardiothorac Surg, Lund, Sweden
[4] Univ Ulm, Dept Cardiol, Ulm, Germany
[5] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, S-41345 Gothenburg, Sweden
[6] Clin Marcapasos SL, Barcelona, Spain
[7] St Jude Med Div Pacesetter, Nuremberg, Germany
[8] Haukeland Univ Hosp, Dept Med A, N-5021 Bergen, Norway
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 08期
关键词
autocapture; Microny; backup pulse; evoked response; Holter; exit block;
D O I
10.1111/j.1540-8159.1998.tb00244.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacing threshold is affected by many factors. A pacing system able to confirm capture at each beat and automatically adjust its output close to the actual pacing threshold is highly desirable. This study evaluates the safety and efficacy of the Autocapture function of the Pacesetter Microny SR +. One hundred thirteen patients were recruited from 16 centers in 7 European countries and followed up for 1 year. All pacemakers were implanted with Pacesetter's low polarization, bipolar leads. The key feature of Autocapture is the immediate delivery of a 4.5 V safety backup pulse 62.5 ms after any ineffective ongoing low output pulse. Holter recordings confirmed total reliability of this feature without any exit block. The measured evoked response (ER) signal was stable over time. Acute and chronic pacing thresholds measured by VARIO and Autocapture tests correlated (r > 0.79) over the period of the study. The incidence of backup pulses was 1.1% during pacing. With Autocapture programmed ON, the overall total current consumption was 4.1 mu A for VVI and 5.0 mu A for VVIR pacing. This study proved that the Autocapture safely and reliably regulates the pacemaker's output according to the prevailing threshold thus providing maximum patient safety and prolonging service life.
引用
收藏
页码:1567 / 1575
页数:9
相关论文
共 11 条
[1]  
CLARKE M, 1987, J ELECTROPHYSIOL, V1, P388
[2]  
Dohrmann M L, 1985, Cardiol Clin, V3, P527
[3]  
EZRI MD, 1983, CLIN PROG PACING ELE, V1, P20
[4]  
FUNKE HD, 1972, THESIS U BONN GERMAN
[5]  
LINDBERG J, 1997, DESCRIPTION FUNCTION
[6]  
MUGICA J, 1973, CARDIAC PACING, P150
[7]  
NATHAN AW, 1984, CLIN PROG PACING ELE, V2, P43
[8]   Improvements in pacemaker energy consumption and functional capability: Four decades of progress [J].
Ohm, OJ ;
Danilovic, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :2-9
[9]   CHANGES IN MYOCARDIAL THRESHOLD . PHYSIOLOGIC AND PHARMACOLOGIC FACTORS IN PATIENTS WITH IMPLANTED PACEMAKERS [J].
PRESTON, TA ;
FLETCHER, RD ;
LUCCHESI, BR ;
JUDGE, RD .
AMERICAN HEART JOURNAL, 1967, 74 (02) :235-&
[10]  
PRESTON TA, 1973, CARDIAC PACING, P295