Radiologist detection of microcalcifications with and without computer-aided detection: A comparative study

被引:45
作者
Brem, RF
Schoonjans, JM
机构
[1] George Washington Univ, Med Ctr, Breast Imaging & Intervent Ctr, Washington, DC 20037 USA
[2] Johns Hopkins Med Inst, Baltimore, MD 21287 USA
关键词
microcalcification; CAD; mammogram;
D O I
10.1053/crad.2000.0592
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare the sensitivity and specificity of microcalcification detection by radiologists alone and assisted by a computer-aided detection (CAD) system. MATERIALS AND METHODS: Films of 106 patients were masked, randomized, digitized and analysed by the CAD-system. Five readers interpreted the original mammograms and were blinded to demographics, medical history and earlier films. Forty-two mammograms with malignant microcalcifications, 40 with benign microcalcifications and 24 normal mammograms were included. Results were recorded on a standardized image interpretation form. The mammograms with suspicious areas flagged by the CAD-system were displayed on mini-monitors and immediately re-reviewed. The interpretation was again recorded on a new copy of the standard form and classified according to six groups. RESULTS: Forty-one out of 42 (98%) malignant microcalcifications and 32 of 40 (80%) benign microcalcifications were flagged by the CAD-system. There was an average of 1.2 markers per image. The sensitivity for malignant microcalcificatioms detection by mammographers without and with the CAD-system ranged from 81% to 98% and from 88% to 98%, respectively. The mean difference without and with CAD-system was 2.2% (range 0-7%). CONCLUSION: No statistically significant changes in sensitivity were found when experienced mammographers were assisted by the CAD-system, with no significant compromise in specificity. Brem, R. F., Schoonjans, J. M. (2001). Clinical Radiology 56, 150-154. (C) 2001 The Royal College of Radiologists.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 29 条
[1]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[2]   Artificial neural network: Improving the quality of breast biopsy recommendations [J].
Baker, JA ;
Kornguth, PJ ;
Lo, JY ;
Floyd, CE .
RADIOLOGY, 1996, 198 (01) :131-135
[3]   Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample [J].
Beam, CA ;
Layde, PM ;
Sullivan, DC .
ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (02) :209-213
[4]   ANALYSIS OF CANCERS MISSED AT SCREENING MAMMOGRAPHY [J].
BIRD, RE ;
WALLACE, TW ;
YANKASKAS, BC .
RADIOLOGY, 1992, 184 (03) :613-617
[5]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[6]   Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces [J].
Chan, HP ;
Sahiner, B ;
Lam, KL ;
Petrick, N ;
Helvie, MA ;
Goodsitt, MM ;
Adler, DD .
MEDICAL PHYSICS, 1998, 25 (10) :2007-2019
[7]   COMPUTER-AIDED DETECTION OF MAMMOGRAPHIC MICROCALCIFICATIONS - PATTERN-RECOGNITION WITH AN ARTIFICIAL NEURAL-NETWORK [J].
CHAN, HP ;
LO, SCB ;
SAHINER, B ;
LAM, KL ;
HELVIE, MA .
MEDICAL PHYSICS, 1995, 22 (10) :1555-1567
[8]   IMPROVEMENT IN RADIOLOGISTS DETECTION OF CLUSTERED MICROCALCIFICATIONS ON MAMMOGRAMS - THE POTENTIAL OF COMPUTER-AIDED DIAGNOSIS [J].
CHAN, HP ;
DOI, K ;
VYBORNY, CJ ;
SCHMIDT, RA ;
METZ, CE ;
LAM, KL ;
OGURA, T ;
WU, YZ ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 (10) :1102-1110
[9]   COMPUTER-AIDED CLASSIFICATION OF MAMMOGRAPHIC MASSES AND NORMAL TISSUE - LINEAR DISCRIMINANT-ANALYSIS IN TEXTURE FEATURE SPACE [J].
CHAN, HP ;
WEI, DT ;
HELVIE, MA ;
SAHINER, B ;
ADLER, DD ;
GOODSITT, MM ;
PETRICK, N .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :857-876
[10]   Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: An ROC study [J].
Chan, HP ;
Sahiner, B ;
Helvie, MA ;
Petrick, N ;
Roubidoux, MA ;
Wilson, TE ;
Adler, DD ;
Paramagul, C ;
Newman, JS ;
Sanjay-Gopal, S .
RADIOLOGY, 1999, 212 (03) :817-827