Correcting spatial distortion in histological images

被引:18
作者
Breen, MS
Lancaster, TL
Wilson, DL [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
medical image processing; image registration; tissue typing; interventional magnetic resonance imaging; thermal ablation; histology;
D O I
10.1016/j.compmedimag.2005.04.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We described an interactive method for correcting spatial distortion in histology samples, applied them to a large set of image data, and quantitatively evaluated the quality of the corrections. We demonstrated registration of histology samples to photographs of macroscopic tissue samples and to MR images. We first described methods for obtaining corresponding fiducial and anatomical points, including a new technique for determining boundary correspondence points. We then describe experimental methods for tissue preparation, including a technique for adding color-coded internal and boundary ink marks that are used to validate the method by measuring the registration error. We applied four different transformations with internal and boundary correspondence points, and measured the distance error between other internal ink fiducials. A large number of boundary points, typically 20-30, and at least two internal points were required for accurate warping registration. Interior errors with the transformation methods were ordered: thin plate spline (TPS) approximate to non-warping << triangle warping < polynomial warping. Although non-warping surprisingly gave the lowest interior distance error (0.5 +/- 0.3 mm), TPS was more robust, gave an insignificantly greater error (0.6 +/- 0.3 mm) and much better results near boundaries where distortion was more evident, and allowed us to correct tom histology samples, a common problem. Using the method to evaluate RF thermal ablation, we found good zonal correlation between MR images and corrected histology samples. The method can be practically applied to this and other emerging applications such as in vivo molecular imaging. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:405 / 417
页数:13
相关论文
共 35 条
[1]  
Akima H., 1978, ACM Transactions on Mathematical Software, V4, P148, DOI 10.1145/355780.355786
[2]  
Aschoff AJ, 2000, J MAGN RESON IMAGING, V12, P584, DOI 10.1002/1522-2586(200010)12:4<584::AID-JMRI10>3.0.CO
[3]  
2-W
[4]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[6]   Three dimensional correlation of MR images to muscle tissue response for interventional MRI thermal ablation [J].
Breen, MS ;
Lazebnik, RS ;
Lewin, JS ;
Wilson, DL .
MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 :202-209
[7]  
Chen L, 2001, J MAGN RESON IMAGING, V13, P23, DOI 10.1002/1522-2586(200101)13:1<23::AID-JMRI1004>3.0.CO
[8]  
2-G
[9]   Utilization of metabolic, transport and receptor-mediated processes to deliver agents for cancer diagnosis [J].
Cutler, CS ;
Lewis, JS ;
Anderson, CJ .
ADVANCED DRUG DELIVERY REVIEWS, 1999, 37 (1-3) :189-211
[10]   A physics-based coordinate transformation for 3-D image matching [J].
Davis, MH ;
Khotanzad, A ;
Flamig, DP ;
Harms, SE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) :317-328