摘要
The longevity of batteries in internal pulse generators (IPGs) used clinically for deep brain stimulation is not known. We conducted a study to assess the life span of these batteries. From 1993 to 2000, 163 single-channel batteries were surgically implanted in our institution. The electrical settings utilized in patients who had battery failures were assessed and the total electrical energy delivered ( TEED) was calculated and correlated with battery longevity. Fourteen IPGs had battery failure requiring replacement. The median life span of the batteries was 45 months. Batteries with high energy consumption as assessed by TEED had a reduced life span (r = - 0.82, p less than or equal to 0.001). Patients with essential tremor who required battery replacement needed higher settings to control their symptoms and therefore presented a shorter battery life when compared to patients with Parkinson's disease. In our series of patients who needed battery replacement, battery longevity varied with stimulation parameters but was longer than expected from the manufacturer's specifications. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 9 条
[1]   Complications of deep brain stimulation surgery [J].
Beric, A ;
Kelly, PJ ;
Rezai, A ;
Sterio, D ;
Mogilner, A ;
Zonenshayn, M ;
Kopell, B .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2001, 77 (1-4) :73-78
[2]   Complications of deep brain stimulation surgery [J].
Hariz, MI .
MOVEMENT DISORDERS, 2002, 17 :S162-S166
[3]   Tolerance and tremor rebound following long-term chronic thalamic stimulation for parkinsonian and essential tremor [J].
Hariz, MI ;
Shamsgovara, P ;
Johansson, F ;
Hariz, GM ;
Fodstad, H .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1999, 72 (2-4) :208-218
[4]   Long-term safety and efficacy of unilateral deep brain stimulation of the thalamus in essential tremor [J].
Koller, WC ;
Lyons, KE ;
Wilkinson, SB ;
Troster, AI ;
Pahwa, R .
MOVEMENT DISORDERS, 2001, 16 (03) :464-468
[5]  
*MEDTR, 2000, MEDTR SOL NEUR ACT P
[6]   The impact on Parkinson's disease of electrical parameter settings in STN stimulation [J].
Moro, E ;
Esselink, RJA ;
Xie, J ;
Hommel, M ;
Benabid, AL ;
Pollak, P .
NEUROLOGY, 2002, 59 (05) :706-713
[7]  
Oh MY, 2002, NEUROSURGERY, V50, P1268
[8]  
*PHYS HOSP STAFF M, 1993, MEDTR ITR 2 QUADR IM
[9]   Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients [J].
Umemura, A ;
Jaggi, JL ;
Hurtig, HI ;
Siderowf, AD ;
Colcher, A ;
Stern, MB ;
Baltuch, GH .
JOURNAL OF NEUROSURGERY, 2003, 98 (04) :779-784