Ultrasonic locating devices for central venous cannulation: meta-analysis

被引:679
作者
Hind, D
Calvert, N
McWilliams, R
Davidson, A
Paisley, S
Beverley, C
Thomas, S
机构
[1] ScHARR, Rapid Reviews Grp, Sheffield S1 4DA, S Yorkshire, England
[2] Fourth Hurdle Consulting, London WC1R 4QA, England
[3] Royal Liverpool Univ Hosp, Liverpool L7 8XP, Merseyside, England
[4] Royal Hallamshire Hosp, Sheffield Teaching Hosp NHS Trust, Sheffield S10 2JF, S Yorkshire, England
[5] Univ Sheffield, No Gen Hosp, Dept Acad Radiol, Sheffield S5 7AU, S Yorkshire, England
来源
BMJ-BRITISH MEDICAL JOURNAL | 2003年 / 327卷 / 7411期
关键词
D O I
10.1136/bmj.327.7411.361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. Data sources 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Design Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. Intervention reviewed Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Data extraction Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. Data synthesis 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Conclusions Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
引用
收藏
页码:361 / 364
页数:6
相关论文
共 9 条
[1]   Statistics Notes - Interaction revisited: the difference between two estimates [J].
Altman, DG ;
Bland, JM .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 326 (7382) :219-219
[2]  
Callum K.G., 2000, Interventional Vascular Radiology and Interventional Neurovascular Radiology: A Report of the National Confidential Enquiry into Perioperative Deaths
[3]  
CALVERT N, 2003, HLTH TECHNOL ASSESS, V7
[4]   GUIDELINES FOR GOOD PRACTICE IN CENTRAL VENOUS CATHETERIZATION [J].
ELLIOTT, TSJ ;
FAROQUI, MH ;
ARMSTRONG, RF ;
HANSON, GC .
JOURNAL OF HOSPITAL INFECTION, 1994, 28 (03) :163-176
[5]  
*NAT I CLIN EXC, 2002, 49 NICE
[6]   Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature [J].
Randolph, AG ;
Cook, DJ ;
Gonzales, CA ;
Pribble, CG .
CRITICAL CARE MEDICINE, 1996, 24 (12) :2053-2058
[7]   EMPIRICAL-EVIDENCE OF BIAS - DIMENSIONS OF METHODOLOGICAL QUALITY ASSOCIATED WITH ESTIMATES OF TREATMENT EFFECTS IN CONTROLLED TRIALS [J].
SCHULZ, KF ;
CHALMERS, I ;
HAYES, RJ ;
ALTMAN, DG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (05) :408-412
[8]  
Sowden AJ, 2001, UNDERTAKING SYSTEMAT
[9]   FEMORAL DEEP-VEIN THROMBOSIS ASSOCIATED WITH CENTRAL VENOUS CATHETERIZATION - RESULTS FROM A PROSPECTIVE, RANDOMIZED TRIAL [J].
TROTTIER, SJ ;
VEREMAKIS, C ;
OBRIEN, J ;
AUER, AI .