Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles

被引:31
作者
Akinboboye, O
Nichols, K
Wang, Y
Dim, UR
Reichek, N
机构
[1] St Fancis Hosp, Div Cardiol, Roslyn, NY 11576 USA
[2] Long Isl Jewish Med Ctr, Div Nucl Med, New Hyde Pk, NY 11042 USA
关键词
cardiac function; radioisotopes; magnetic resonance imaging;
D O I
10.1016/j.nuclcard.2005.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We compared gated blood pool single photon emission computed tomography (SPECT) (GBPS), planar gated blood pool imaging (planar GBP), and cardiac magnetic resonance (CMR) measurements of left ventricular (LV) end-diastolic volume (EDV) and ejection fraction (EF) in patients with abnormal left ventricles. Methods and Results. LV functional parameters were measured for 40 subjects (age, 59 +/- 13 years; 85% male) by GBPS, planar GBP, and CMR. GBPS data were analyzed by use of count-threshold software (BP-SPECT) and surface gradient software (QBS). Limits of agreement with CMR for EF were -5% to +18%, -15% to +14%, and -15% to +16% for BP-SPECT, QBS, and planar GBP, respectively. However, limits of agreement with CMR for LV EDV were wide by both GBPS methods: -118 mL to +55 mL and -143 mL to +22 mL for BP-SPECT and QBS, respectively. Bland-Altman reproducibility limits for EF were -9% to +8%, -6% to +9%, and -7% to +7% by BP-SPECT, QBS, and planar GBP, respectively, and those for EDV were -46 mL to +48 mL and -31 mL to +35 mL by BP-SPECT and QBS, respectively. Conclusion. GBPS LV EF measurements agree with measurements by CMR and are as reproducible as planar GBP measurements. However, wide limits of agreement of radionuclide versus CMR values suggest that caution must be applied in interpreting GBPS LV volume results, especially for patients with markedly abnormal left ventricles.
引用
收藏
页码:418 / 427
页数:10
相关论文
共 20 条
[1]  
*AM SOC NUCL CARD, 2001, J NUCL CARDIOL, V8, pG1
[2]  
Bartlett ML, 1996, J NUCL MED, V37, P1795
[3]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[4]  
CHRISTIAN PE, 1985, J NUCL MED, V26, P775
[5]  
Faber TL, 1999, J NUCL MED, V40, P650
[6]   THE NATURAL-HISTORY OF IDIOPATHIC DILATED CARDIOMYOPATHY [J].
FUSTER, V ;
GERSH, BJ ;
GIULIANI, ER ;
TAJIK, AJ ;
BRANDENBURG, RO ;
FRYE, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (03) :525-531
[7]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[8]   THE USE OF REST AND EXERCISE RADIONUCLIDE VENTRICULOGRAPHY IN RISK STRATIFICATION IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE [J].
ISKANDRIAN, AS ;
HAKKI, AH ;
GOEL, IP ;
MUNDTH, ED ;
KANEMARSCH, SA ;
SCHENK, CL .
AMERICAN HEART JOURNAL, 1985, 110 (04) :864-872
[9]   INVIVO MEASUREMENT OF MYOCARDIAL MASS USING NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
KELLER, AM ;
PESHOCK, RM ;
MALLOY, CR ;
BUJA, LM ;
NUNNALLY, R ;
PARKEY, RW ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) :113-117
[10]   Model dependence of gated blood pool SPECT ventricular function measurements [J].
Nichols, K ;
Humayun, N ;
De Bondt, P ;
Vandenberghe, S ;
Akinboboye, OO ;
Bergmann, SR .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) :282-292