Clinical validation of SPECT attenuation correction using X-ray computed tomography-derived attenuation maps: Multicenter clinical trial with angiographic correlation

被引:135
作者
Masood, Y
Liu, YH
DePuey, G
Taillefer, R
Araujo, LI
Allen, S
Delbeke, D
Anstett, F
Peretz, A
Zito, MJ
Tsatkin, V
Wackers, FJT
机构
[1] Yale Univ, Sch Med, Cardiovasc Nucl Imaging Lab, New Haven, CT 06520 USA
[2] St Lukes Roosevelt Hosp, Dept Nucl Med, New York, NY USA
[3] Hotel Dieu Mintreal, Dept Nucl Med, Montreal, PQ, Canada
[4] Univ Penn, Dept Nucl Med, Philadelphia, PA USA
[5] Mercy Med Ctr, Dept Nucl Med, Springfield, MA USA
[6] GE Healthcare, Waukesha, WI USA
[7] Vanderbilt Univ, Dept Nucl Med, Nashville, TN USA
关键词
single photon emission computed tomography; computed X-ray tomography; attenuation correction; coronary artery disease;
D O I
10.1016/j.nuclcard.2005.08.006
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. Nonuniform attenuation artifacts cause suboptimal specificity of stress single photon emission computed tomography (SPECT) myocardial perfusion images. In phantoms, normal subjects, and patients suspected of having coronary artery disease (CAD), we evaluated a new hybrid attenuation correction (AC) system that combines x-ray computed tomography (CT) with conventional stress SPECT imaging. Methods and Results. The effect of CT-based AC was evaluated in phantoms by assessing homogeneity of normal cardiac inserts. AC improved homogeneity of normal cardiac phantoms from 11% +/- 2% to 5% +/- 1% (P < .001). Attenuation-corrected normal patient files were created from 37 normal subjects with a low likelihood (< 3%) of CAD. The diagnostic performance of AC for detection of CAD was evaluated in 118 patients who had stress technetium 99m sestamibi or tetrofosmin stress SPECT imaging and coronary angiography. SPECT images with and without AC were interpreted by 4 blinded readers with different interpretative attitudes. Overall, AC improved the diagnostic performance of all readers, particularly the normalcy rate. The degree of improvement depended on interpretative attitude. Readers prone to high sensitivity or with less experience had the greatest gain in the normalcy rate, whereas a reader prone to higher specificity had improvements in sensitivity and specificity but not the normalcy rate. Importantly, improvement of one diagnostic variable was not associated with worsening of other variables. Conclusion. CT-based AC of SPECT images consistently improved overall diagnostic performance of readers with different interpretive attitudes and experience. CT-based AC is well suited for routine use in clinical practice.
引用
收藏
页码:676 / 686
页数:11
相关论文
共 40 条
[1]
Clinical implication of down-scatter in attenuation-corrected myocardial SPECT [J].
Almquist, H ;
Arheden, H ;
Arvidsson, AH ;
Pahlm, O ;
Palmer, J .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) :406-411
[2]
Araujo LI, 2000, J NUCL MED, V41, P1139
[3]
BAILEY DL, 1987, J NUCL MED, V28, P844
[4]
Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images [J].
Bocher, M ;
Balan, A ;
Krausz, Y ;
Shrem, Y ;
Lonn, A ;
Wilk, M ;
Chisin, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :619-627
[5]
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) :240-245
[6]
Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease [J].
Chouraqui, P ;
Livschitz, S ;
Sharir, T ;
Wainer, N ;
Wilk, M ;
Moalem, I ;
Baron, J .
JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (04) :369-377
[7]
De Santis Fulvio, 2004, Ann Ist Super Sanita, V40, P173
[8]
DEPUEY EG, 1994, J NUCL MED, V35, P699
[9]
Updated imaging guidelines for nuclear cardiology procedures, part 1 [J].
DePuey, EG ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (01) :G3-G58
[10]
DO FALSE POSITIVE TL-201 SCANS LEAD TO UNNECESSARY CATHETERIZATION - OUTCOME OF PATIENTS WITH PERFUSION DEFECTS ON QUANTITATIVE PLANAR TL-201 SCINTIGRAPHY [J].
DESMARAIS, RL ;
KAUL, S ;
WATSON, DD ;
BELLER, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) :1058-1063