Parallel computing was tested regarding its ability to speed up chemometric operations for data analysis. A set of metabolic samples from a second hand smoke (SHS) experiment was analyzed with comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC x GC-TOFMS). Data was further preprocessed and analyzed. The preprocessing step comprises background correction, smoothing and alignment of the chromatographic signal. Data analysis was performed by applying t-test and partial least squares projection to latent structures discriminant analysis (PLS-DA). The optimization of the algorithm for parallel computing led to a substantial increase in performance. Metabolic fingerprinting showed a discrimination of the samples and indicates a metabolic effect of SHS. (C) 2010 Published by Elsevier B.V.
引用
收藏
页码:1289 / 1294
页数:6
相关论文
共 43 条
[1]   Integrative Normalization and Comparative Analysis for Metabolic Fingerprinting by Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry [J].
Almstetter, Martin F. ;
Appel, Inka J. ;
Gruber, Michael A. ;
Lottaz, Claudia ;
Timischl, Birgit ;
Spang, Rainer ;
Dettmer, Katja ;
Oefnert, Peter J. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5731-5739
[2]  
BARRY KL, 2005, CHEMOMETRICS CHEMOIN, P1
[3]   Comprehensive two-dimensional gas chromatography - a powerful and widely applicable technique [J].
Beens, J ;
Brinkman, UAT .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) :1939-1943
[4]   Knowledge discovery in metabolomics: An overview of MS data handling [J].
Boccard, Julien ;
Veuthey, Jean-Luc ;
Rudaz, Serge .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (03) :290-304
[5]   Critical factors limiting the interpretation of regression vectors in multivariate calibration [J].
Brown, Christopher D. ;
Green, Robert L. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (04) :506-514
[6]   OPLS discriminant analysis:: combining the strengths of PLS-DA and SIMCA classification [J].
Bylesjo, Max ;
Rantalainen, Mattias ;
Cloarec, Olivier ;
Nicholson, Jeremy K. ;
Holmes, Elaine ;
Trygg, Johan .
JOURNAL OF CHEMOMETRICS, 2006, 20 (8-10) :341-351
[7]   Chromatographic preprocessing of GC-MS data for analysis of complex chemical mixtures [J].
Christensen, JH ;
Mortensen, J ;
Hansen, AB ;
Andersen, O .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :113-123
[8]   Use and abuse of chemometrics in chromatography [J].
Daszykowski, Michal ;
Walczak, Beata .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (11) :1081-1096
[9]  
DATTA S, 2007, METABOLIC ALTERATION
[10]   Mass spectrometry-based metabolomics [J].
Dettmer, Katja ;
Aronov, Pavel A. ;
Hammock, Bruce D. .
MASS SPECTROMETRY REVIEWS, 2007, 26 (01) :51-78