Development of a poly(dimethylsiloxane) interface for on-line capillary column liquid chromatography-capillary electrophoresis coupled to sheathless electrospray ionization time-of-flight mass spectrometry

被引:33
作者
Bergström, SK [1 ]
Samskog, J [1 ]
Markides, KE [1 ]
机构
[1] Uppsala Univ, Dept Analyt Chem, SE-75124 Uppsala, Sweden
关键词
D O I
10.1021/ac030117g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An interface in elastomeric poly(dimethylsiloxane) (PDMS) for on-line orthogonal coupling of packed capillary liquid chromatography (LC) (i.d. = 0.2 mm) with capillary electrophoresis (CE) in combination with sheathless electrospray ionization (ESI) time-of-flight mass spectrometric (TOFMS) detection is presented. The new interface has a two-level design, which in combination with a continuous CE electrolyte flow through the interface provides integrity of the LC effluent and the CE separation until an injection is desired. The transparent and flexible PDMS material was found to have a number of advantages when combined with fused silica column technology, including ease to follow the process and ease to exchange columns. By combining conventional microscale systems of LC, CE, and ESI-MS, respectively, the time scales of the individual dimensions were harmonized for optimal peak capacity per unit time. The performance of the LC-CE-TOFMS system was evaluated using peptides as model substances. A S/N of about 330 was achieved for leucineenkephaline from a 0.5 muL LC injection of 25 mug/mL peptide standard.
引用
收藏
页码:5461 / 5467
页数:7
相关论文
共 35 条
[1]  
Bowser MT, 2001, ELECTROPHORESIS, V22, P3668, DOI 10.1002/1522-2683(200109)22:17<3668::AID-ELPS3668>3.0.CO
[2]  
2-M
[3]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[4]  
2-M
[5]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[6]   Micro devices integrated with microchannels and electrospray nozzles using PDMS casting techniques [J].
Chiou, CH ;
Lee, GB ;
Hsu, HT ;
Chen, PW ;
Liao, PC .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3) :280-286
[7]   Reversed-phase capillary liquid chromatography coupled on-line to capillary electrophoresis immunoassays [J].
German, I ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5365-5372
[8]  
German I, 2001, ELECTROPHORESIS, V22, P3659, DOI 10.1002/1522-2683(200109)22:17<3659::AID-ELPS3659>3.0.CO
[9]  
2-I
[10]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323