Retinal thickness variation in the diabetic patient measured by the retinal thickness analyser

被引:31
作者
Weinberger, D [1 ]
Axer-Siegel, R
Landau, D
Yassur, Y
机构
[1] Beilinson Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
[3] Shaare Zedek Hosp, Eye Dept, Jerusalem, Israel
关键词
D O I
10.1136/bjo.82.9.1003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim-To evaluate the potential of the retinal thickness analyser (RTA) as an objective tool for assessment and follow up of diabetic macular oedema. Methods-A prototype of the RTA that operates on the principle of laser slit biomicroscopy was used. Retinal thickness was obtained in 41 eyes of 41 diabetic patients. The clinical diagnosis was cystoid macular oedema (CMO) in 10 eyes, clinically significant macular oedema (CSMO) without retinal cysts in 21 eyes, and "dry" macula following grid pattern laser treatment in 10 eyes. The control group consisted of 46 eyes of age matched healthy volunteers. Results-In normal eyes (46 eyes), the foveal thickness measured was 178 (SD 44) Irm and the macular thickness around the fovea was 311 (51) mu m The eyes with CMO displayed the largest foveal thickening, 875 (287) mu m (390% increase compared with normal values). The average thickness of the fovea in the non-cystoid CSMO group was 427 (175) mu m (144% increase compared with normal fovea). The average thickness of the foveal centre in eyes judged as having "dry" macula after laser treatment was 315 (71) mu m (77% increase compared with normal value and a 26% decrease in thickness compared with the CSMO eyes). Statistically significant differences were found in central thickness between these four groups (p = 0.0001). The average thickness at 500 mu m surrounding the fovea was 566 (202) inn in the CSMO eyes compared with 311 (51) mu m in normal eyes (80% increase). The "dry" macula group (after undergoing laser treatments) had an average thickness of 414 (94) mu m (27% decrease compared with CSMO eyes and a 33% increase compared with eyes of healthy controls). Conclusions-RTA is a system for quantifying macular thickness and imaging of macular pathology. The system can be a useful tool for diagnosis of macular diseases and for evaluation of the effect of treatment modalities.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 9 条
[1]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P741
[2]  
ARSANI S, 1997, OPHTHALMOLOGY, V104, P1145
[3]   Quantitative in vivo retinal thickness measurements in healthy subjects [J].
Landau, D ;
Schneidman, EM ;
Jacobovitz, T ;
Rozenman, Y .
OPHTHALMOLOGY, 1997, 104 (04) :639-642
[4]  
MORI M T, 1989, Investigative Ophthalmology and Visual Science, V30, P175
[5]   RETINAL THICKNESS CHANGE AFTER FOCAL LASER TREATMENT OF DIABETIC MACULAR EDEMA [J].
SHAHIDI, M ;
OGURA, Y ;
BLAIR, NP ;
ZEIMER, R .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (11) :827-830
[6]   RETINAL THICKNESS ANALYSIS FOR QUANTITATIVE ASSESSMENT OF DIABETIC MACULAR EDEMA [J].
SHAHIDI, M ;
OGURA, Y ;
BLAIR, NP ;
RUSIN, MM ;
ZEIMER, R .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (08) :1115-1119
[7]  
SHAHIDI M, 1990, OPHTHALMOLOGY, V97, P1120
[8]  
Zeimer R, 1996, INVEST OPHTH VIS SCI, V37, P1994
[9]   INVIVO EVALUATION OF A NONINVASIVE METHOD TO MEASURE THE RETINAL THICKNESS IN PRIMATES [J].
ZEIMER, RC ;
SHAHIDI, M ;
MORI, MT ;
BENHAMOU, E .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (07) :1006-1009