Development of gold contacted flip-chip detectors with IMARAD CZT

被引:10
作者
Narita, T [1 ]
Bloser, PF [1 ]
Grindlay, JE [1 ]
Jenkins, JA [1 ]
机构
[1] Harvard Smithsonian Ctr Astrophys, Cambridge, MA 02138 USA
来源
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II | 2000年 / 4141卷
关键词
CdZnTe; pixellated imaging detectors; hard X-ray imaging;
D O I
10.1117/12.407569
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present initial results from our evaluation of a gold-contacted pixellated detector using cadmium zinc telluride substrate produced by IMARAD Imaging Systems. The Horizontal Bridgman (HB) grown crystals from IMARAD have been shown to produce high resolution photopeaks, but they are also seen to have large leakage current. Our previous tests with IMARAD CZT showed that the use of indium anodes and gold cathode improved the resistivity compared to the standard indium-contacted detectors. We seek to test whether simple evaporated gold contacts alone could also reduce the leakage current and thus improve the spectral resolution, especially in the 10-100 keV energy range. We have fabricated several metal-semiconductor-metal (MSM) detectors with a 4 x 4 array of pixels on 10 x 10 mm substrates. Measurements of the detectors' leakage current, spectral response, and temperature sensitivity are presented and compared to IMARAD's ohmic contact detector and gold contact MSM detectors made of High Pressure Bridgman (HPB) material. Finally, we show preliminary results from a tiled flip-chip pixellated detector made using the IMARAD detectors.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 10 条
[1]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[2]  
BLOSER P, 2000, P SPIE, V4140
[3]  
CHEUVART P, 1990, J CRYSTAL GROWTH, V101
[4]  
ELHANANY U, COMMUNICATION
[5]  
Grindlay J, 2000, AIP CONF PROC, V510, P784
[6]   Development of prototype pixellated PIN CdZnTe detectors [J].
Narita, T ;
Bloser, P ;
Grindlay, J ;
Sudharsanan, R ;
Reiche, C ;
Stenstrom, C .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND APPLICATIONS, 1998, 3446 :218-227
[7]   Development of IMARAD CZT detectors with PIN contacts [J].
Narita, T ;
Bloser, PF ;
Grindlay, JE ;
Jenkins, JA ;
Yao, HW .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 :55-65
[8]  
SCHLESINGER T, 1998, 2 6 WORKSH
[9]   Role of uniformity and geometry in IMARAD-type gamma-ray spectrometers [J].
Schlesinger, TE ;
Greaves, M ;
Ross, S ;
Brunett, BA ;
Van Scyoc, JM ;
James, RB .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 :16-26
[10]  
SHOR A, 1999, NIM, V403, P417