The effect of impurity cations on the oxygen reduction kinetics at platinum electrodes covered with perfluorinated ionomer

被引:83
作者
Okada, T
Ayato, Y
Satou, H
Yuasa, M
Sekine, I
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058565, Japan
[2] Sci Univ Tokyo, Fac Sci & Technol, Dept Ind Chem, Noda, Chiba 2788510, Japan
来源
JOURNAL OF PHYSICAL CHEMISTRY B | 2001年 / 105卷 / 29期
关键词
D O I
10.1021/jp010822y
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The mechanism of how impurity cations suppress the kinetics of oxygen reduction reaction on platinum surface covered with perfluoro-sulfonated ionomer film was studied in 0.1 N H2SO4 in the presence of various kinds of impurity ions of several concentrations. Impurity cations tested were Li+, Na+, K+, Ca2+, Fe3+, Ni2+, and Cu2+ with the amount of 0.1%, 1%, and 10% as compared with H+ in the solution. Platinum disk of a rotating disk electrode was spin-coated with Nafion solution, and after drying the Nafion film-covered platinum was obtained. The electrochemical measurements were performed to evaluate both charge transfer and diffusion kinetics of oxygen reduction at the Nafion film-covered electrode. It was discovered that the impurity ions hindered enormously the rate of charge-transfer step at platinum covered with perfluoro-sulfonated ionomer. The suppression started already at 0.1% level of impurity concentration, but did not increase much at over 1% level. No suppression effect for oxygen reduction was observed for a bare platinum in the solution containing impurity ions, indicating that the effect is specific to the metal electrode-ionomer membrane interface. Also both the diffusion coefficient of oxygen and oxygen concentration in the membrane decreased by the presence of impurity cations. It was implied that all the process is related to the reorientation of polymer networks in the membrane, which might bring about the modification of electric double layer at the platinum-ionomer interface.
引用
收藏
页码:6980 / 6986
页数:7
相关论文
共 21 条
  • [1] EFFECT OF UNDERPOTENTIAL DEPOSITION (UPD) OF COPPER ON OXYGEN REDUCTION AT PT(111) SURFACES
    ABE, T
    SWAIN, GM
    SASHIKATA, K
    ITAYA, K
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2): : 73 - 83
  • [2] BARD AJ, 1980, ELECTROCHEMICAL METH
  • [3] Behavior of perfluorinated surfactants at the electrode/solution interface
    Cha, CS
    Zu, YB
    [J]. LANGMUIR, 1998, 14 (21) : 6280 - 6286
  • [4] GILEADI E, 1993, ELECTRODE KINETICS
  • [5] OXYGEN REDUCTION KINETICS ON A PLATINUM RDE COATED WITH A RECAST NAFION1 FILM
    GOTTESFELD, S
    RAISTRICK, ID
    SRINIVASAN, S
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (06) : 1455 - 1462
  • [6] Discreteness of charge effects on the double layer structure at the metal/solid electrolyte interface
    Horrocks, BR
    Armstrong, RD
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (51): : 11332 - 11338
  • [7] Kinoshita K., 1992, Electrochemical Oxygen Technology
  • [8] OXYGEN REDUCTION AT NAFION FILM-COATED PLATINUM-ELECTRODES - TRANSPORT AND KINETICS
    LAWSON, DR
    WHITELEY, LD
    MARTIN, CR
    SZENTIRMAY, MN
    SONG, JI
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (09) : 2247 - 2253
  • [9] PROCEDURE FOR PREPARING SOLUTION-CAST PERFLUOROSULFONATE IONOMER FILMS AND MEMBRANES
    MOORE, RB
    MARTIN, CR
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (12) : 2569 - 2570
  • [10] Transport and equilibrium properties of Nafion® membranes with H+ and Na+ ions
    Okada, T
    Moller-Holst, S
    Gorseth, O
    Kjelstrup, S
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 442 (1-2) : 137 - 145