The importance of the treatment plant performance during rain to acute water pollution

被引:51
作者
Rauch, W [1 ]
Harremoes, P [1 ]
机构
[1] TECH UNIV DENMARK, INST ENVIRONM SCI & ENGN, DK-2800 LYNGBY, DENMARK
关键词
water pollution; dissolved oxygen depletion; integrated urban drainage system; wastewater treatment plant; combined sewer overflow; river; modeling; systems analysis;
D O I
10.1016/0273-1223(96)00549-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Rain causes not only pollution loads from combined sewer overflows but also from treatment plants. High hydraulic load conditions can affect the secondary clarifier performance, resulting in a massive loss of sludge from the plant. The consequence to the oxygen concentration in the recipient can be described by the same simplified mechanism, because the principle remains the same. The difference that has to be accounted for, is the different organic characteristics of the discharged water. The analysis of a hypothetical urban drainage system by means of a deterministic model reveals the importance of the treatment plant in this respect. Oxygen depletion in urban rivers is caused by intermittent discharges from both sewer system and wastewater treatment plant. Neglecting one of them in the evaluation of the environmental impact gives a wrong impression of total system behavior. Linear sensitivity analysis provides useful information for Water quality management. The significant parameters in terms of acute water pollution are identified. Copyright (C) 1996 IAWQ. Published by Elsevier Science Ltd.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 7 条