Evaluation of the MagNA pure LC used with the TRUGENE™ HBV Genotyping Kit

被引:14
作者
Gintowt, AA [1 ]
Germer, JJ [1 ]
Mitchell, PS [1 ]
Yao, JDC [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Lab Med & Pathol, Div Clin Microbiol, Rochester, MN 55905 USA
关键词
hepatitis B virus; genotyping; MagNA pure LC; TRUGENE;
D O I
10.1016/j.jcv.2005.05.008
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: The current manual sample processing method recommended for use with the TRUGENE(TM) HBV Genotyping Kit (TRUGENE HBV; Bayer HealthCare LLC, Tarrytown, NY) is labor-intensive and may be prone to specimen cross-contamination. Recent evaluations of the MagNA Pure LC (MP; Roche Applied Science, Indianapolis, IN) suggest that it is suitable for automated, contamination-free extraction and purification of viral nucleic acids from large-volume (1.0 mL) serum or plasma specimens. Objectives: We evaluated the MP Total Nucleic Acid Isolation Kit-Large Volume (Roche Applied Science) in conjunction with TRUGENE HBV to establish the analytical sensitivity (threshold titer) of the assay, in HBV DNA International Units (IU)/mL, for obtaining consistent, interpretable sequence data from TRUGENE HBV. Study design: HBV analytical standards, prepared as 10 replicates (1.0 mL each) at each of the following concentrations: 200, 1000, 5000, and 10,000 IU/mL, were processed by MP and analyzed by TRUGENE HBV according to manufacturer's instructions. Performance of TRUGENE HBV used in conjunction with MP sample processing was evaluated further using 22 clinical serum specimens containing low titers of HBV DNA. Results: All replicates of HBV analytical standards at 1000, 5000, and 10,000 IU/mL yielded interpretable TRUGENE HBV sequences, whereas interpretable sequences were obtained in 90% (9 of 10) of the replicates at 200 IU/mL. TRUGENE HBV sequences were interpretable in 86% (19 of 22) of the clinical specimens studied. Conclusions: MP sample processing is efficient and suitable for use with TRUGENE HBV. When combined with MP sample processing, TRUGENE HBV yielded interpretable sequences from HBV analytical standards and clinical serum specimens with HBV DNA titers of >= 200 IU/mL. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 157
页数:3
相关论文
共 6 条
[1]   Mechanisms of disease: Hepatitis B virus infection - Natural history and clinical consequences [J].
Ganem, D ;
Prince, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (11) :1118-1129
[2]   Automated sample preparation for the TRUGENE HIV-1 genotyping kit using the MagNA Pure LC instrument [J].
Germer, JJ ;
Vandenameele, JN ;
Mitchell, PS ;
Harmsen, WS ;
Yao, JDC .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2004, 49 (01) :59-61
[3]   Evaluation of the MagNA pure LC instrument for extraction of hepatitis C virus RNA for the COBAS AMPLICOR hepatitis C Virus Test, version 2.0 [J].
Germer, JJ ;
Lins, MM ;
Jensen, ME ;
Harmsen, WS ;
Ilstrup, DM ;
Mitchell, PS ;
Cockerill, FR ;
Patel, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (08) :3503-3508
[4]   Hepatitis B viral resistance: mechanisms and diagnosis [J].
Locarnini, S .
JOURNAL OF HEPATOLOGY, 2003, 39 :S124-S132
[5]   The hepatitis B virus and common mutants [J].
Locarnini, S ;
McMillan, J ;
Bartholomeusz, A .
SEMINARS IN LIVER DISEASE, 2003, 23 (01) :5-20
[6]  
Zoulim F, 2004, ANTIVIR RES, V64, P1, DOI 10.1016/S0166-3542(04)00162-7