Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces

被引:39
作者
Correa, Cassia Bellotto [1 ]
Pires, Juliana Rico [2 ]
Fernandes-Filho, Romeu Belon [2 ]
Sartori, Rafael [2 ]
Vaz, Luis Geraldo [1 ]
机构
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, UNESP, BR-14800000 Araraquara, SP, Brazil
[2] Sao Paulo State Univ, Dept Periodontol, UNESP, BR-14800000 Araraquara, SP, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2009年 / 18卷 / 05期
基金
巴西圣保罗研究基金会;
关键词
Fluoride; corrosion; dental implants; bacterial adhesion;
D O I
10.1111/j.1532-849X.2009.00463.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Purpose: The influence of fatigue and the fluoride ion corrosion process on Streptococcus mutans adherence to commercially pure Titanium (Cp Ti) implant/component set surfaces were studied. Materials and Methods: Thirty Nobel implants and 30 Neodent implants were used. Each commercial brand was divided into three groups. Group A: control, Group B: sets submitted to fatigue (105 cycles, 15 Hz, 150 N), and Group C: sets submitted to fluoride (1500 ppm, pH 5.5) and fatigue, simulating a mean use of 5 years in the oral medium. Afterward, the sets were contaminated with standard strains of S. mutans (NTCC 1023) and analyzed by scanning electronic microscopy (SEM) and colony-forming unit counts (CFU/mL). Results: By SEM, bacterial adherence was verified only in group C in both brands. By CFU/mL counts, S. mutans was statistically higher in both brands in group C than in groups A and B (p < 0.05, ANOVA). Conclusion: The process of corrosion by fluoride ions on Cp Ti implant/component sets allowed greater S. mutans adherence than in the absence of corrosion and with the fatigue process in isolation.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 28 条
[1]
BARJJ A, 1976, ENCY ELECTROCHEMISTR, V5, P305
[2]
Basten C H, 1996, Int J Oral Maxillofac Implants, V11, P522
[3]
The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis [J].
Bollen, CML ;
Papaioanno, W ;
VanEldere, J ;
Schepers, E ;
Quirynen, M ;
vanSteenberghe, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :201-211
[4]
THE TRANSMANDIBULAR IMPLANT - A 13-YEAR SURVEY OF ITS USE [J].
BOSKER, H ;
JORDAN, RD ;
SINDETPEDERSEN, S ;
KOOLE, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (05) :482-492
[5]
Fluoride concentration in saliva after use of oral hygiene products [J].
Campus, G ;
Lallai, MR ;
Carboni, R .
CARIES RESEARCH, 2003, 37 (01) :66-70
[6]
DONACHIE MJ, 1987, TITANIUM TECHNICAL G, P9
[7]
Drake DR, 1999, INT J ORAL MAX IMPL, V14, P226
[8]
In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants [J].
Fathi, MH ;
Salehi, M ;
Saatchi, A ;
Mortazavi, V ;
Moosavi, SB .
DENTAL MATERIALS, 2003, 19 (03) :188-198
[9]
ADHERENCE OF STREPTOCOCCUS-MUTANS TO IMPLANT MATERIALS [J].
FUJIOKAHIRAI, Y ;
AKAGAWA, Y ;
MINAGI, S ;
TSURU, H ;
MIYAKE, Y ;
SUGINAKA, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (07) :913-920
[10]
GRAVES SL, 1992, AUST PROSTHODONT J, V7, P353