Effluent Volume in Continuous Renal Replacement Therapy Overestimates the Delivered Dose of Dialysis

被引:88
作者
Claure-Del Gramdo, Rolando [1 ]
Macedo, Etienne [1 ]
Chertow, Glenn M. [2 ]
Soroko, Sharon [1 ]
Himmelfarb, Jonathan [3 ]
Ikizler, T. Alp [4 ]
Paganini, Emil P. [5 ]
Mehta, Ravindra L. [1 ]
机构
[1] Univ Calif San Diego, Dept Med, Div Nephrol & Hypertens, San Diego, CA 92103 USA
[2] Stanford Univ, Sch Med, Dept Med, Div Nephrol, Stanford, CA 94305 USA
[3] Univ Washington, Kidney Res Inst, Dept Med, Div Nephrol, Seattle, WA 98195 USA
[4] Vanderbilt Univ, Med Ctr, Dept Med, Div Nephrol, Nashville, TN USA
[5] Cleveland Clin Fdn, Dept Med, Div Nephrol, Cleveland, OH 44195 USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2011年 / 6卷 / 03期
基金
美国国家卫生研究院;
关键词
ACUTE KIDNEY INJURY; CRITICALLY-ILL PATIENTS; CONTINUOUS VENOVENOUS HEMOFILTRATION; FAILURE; HEMODIALYSIS; OUTCOMES; QUANTIFICATION; EPIDEMIOLOGY; INTENSITY; MORBIDITY;
D O I
10.2215/CJN.02500310
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives Studies examining dose of continuous renal replacement therapy (CRRT) and outcomes have yielded conflicting results. Most studies considered the prescribed dose as the effluent rate represented by ml/kg per hour and reported this volume as a surrogate of solute removal. Because filter fouling can reduce the efficacy of solute clearance, the actual delivered dose may be substantially lower than the observed effluent rate. Design, setting, participants, & measurements Data were examined from 52 critically ill patients with acute kidney injury (AKI) requiring dialysis. All patients were treated with predilution continuous venovenous hemodiafiltration (CVVHDF) and regional citrate anticoagulation. Filter performance was monitored during the entire course of therapy by measuring blood urea nitrogen (BUN) and dialysis fluid urea nitrogen (FUN) at initiation and every 12 hours. Filter efficacy was assessed by calculating FUN/BUN ratios every 12 hours of filter use. Prescribed urea clearance (K, ml/min) was determined from the effluent rate. Actual delivered urea clearance was determined using dialysis-side measurements. Results Median daily treatment time was 1413 minutes (1260 to 1440) with a total effluent volume of 46.4 +/- 17.4 L and urea mass removal of 13.0 +/- 7.6 mg/min. Prescribed clearance overestimated the actual delivered clearance by 23.8%. This gap between prescribed and delivered clearance was related to the decrease in filter function assessed by the FUN/BUN ratio. Conclusions Effluent volume significantly overestimates delivered dose of small solutes in CRRT. To assess adequacy of CRRT, solute clearance should be measured rather than estimated by the effluent volume. Clin J Am Soc Nephrol 6: 467-475, 2011. doi: 10.2215/CJN.02500310
引用
收藏
页码:467 / 475
页数:9
相关论文
共 33 条
  • [1] Acute kidney injury criteria predict outcomes of critically ill patients
    Barrantes, Fidel
    Tian, Jianmin
    Vazquez, Rodrigo
    Amoateng-Adjepong, Yaw
    Manthous, Constantine A.
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (05) : 1397 - 1403
  • [2] Acute renal failure - definition, outcome measures, animal models, fluid therapy and information technology needs: the Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group
    Bellomo, R
    Ronco, C
    Kellum, JA
    Mehta, RL
    Palevsky, P
    [J]. CRITICAL CARE, 2004, 8 (04): : R204 - R212
  • [3] Bellomo R, 2009, NEW ENGL J MED, V361, P1627, DOI 10.1056/NEJMoa0902413
  • [4] Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates
    Brunet, S
    Leblanc, M
    Geadah, D
    Parent, D
    Courteau, S
    Cardinal, J
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (03) : 486 - 492
  • [5] CLARK WR, 1994, J AM SOC NEPHROL, V4, P1413
  • [6] Dose determinants in continuous renal replacement therapy
    Clark, WR
    Turk, JE
    Kraus, MA
    Gao, DY
    [J]. ARTIFICIAL ORGANS, 2003, 27 (09) : 815 - 820
  • [7] Clark WR, 1997, J AM SOC NEPHROL, V8, P804
  • [8] Measurement of the delivery of dialysis in acute renal failure
    Evanson, JA
    Ikizler, TA
    Wingard, R
    Knights, S
    Shyr, Y
    Schulman, G
    Himmelfarb, J
    Hakim, RM
    [J]. KIDNEY INTERNATIONAL, 1999, 55 (04) : 1501 - 1508
  • [9] Prescribed versus delivered dialysis in acute renal failure patients
    Evanson, JA
    Himmelfarb, J
    Wingard, R
    Knights, S
    Shyr, Y
    Schulman, G
    Ikizler, TA
    Hakim, RM
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (05) : 731 - 738
  • [10] EFFECT OF PLASMA-PROTEINS ON THE SIEVING SPECTRA OF HEMOFILTERS
    FELDHOFF, P
    TURNHAM, T
    KLEIN, E
    [J]. ARTIFICIAL ORGANS, 1984, 8 (02) : 186 - 192