Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit

被引:18
作者
Ferreira, AMR
Lima, JLFC
Rangel, AOSS
机构
[1] UNIV CATOLICA PORTUGUESA, ESCOLA SUPER BIOTECNOL, P-4200 Porto, PORTUGAL
[2] FAC FARM, DEPT QUIM FIS,CEQUP, P-4050 Porto, PORTUGAL
来源
AUSTRALIAN JOURNAL OF SOIL RESEARCH | 1996年 / 34卷 / 04期
关键词
ammonium ion-selective electrode;
D O I
10.1071/SR9960503
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
A flow injection analysis (FIA) system incorporating a gas-diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas-permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2-ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always < 5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation < 3%).
引用
收藏
页码:503 / 510
页数:8
相关论文
共 22 条
[1]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[2]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[3]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[4]  
BANWART W L, 1972, Communications in Soil Science and Plant Analysis, V3, P449, DOI 10.1080/00103627209366401
[5]  
BREMNER J M, 1972, Communications in Soil Science and Plant Analysis, V3, P159, DOI 10.1080/00103627209366361
[6]   OPTIMIZATION OF PARAMETERS FOR GAS-DIFFUSION FLOW-INJECTION SYSTEMS [J].
CANHAM, JS ;
GORDON, G ;
PACEY, GE .
ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) :157-163
[7]  
DESCHREIDER AR, 1973, ANALUSIS, V2, P442
[8]   FLOW-INJECTION SYSTEMS WITH A STREAM SPLITTING AND A DIALYSIS UNIT FOR THE SOIL ANALYSIS OF SODIUM AND POTASSIUM BY FLAME EMISSION-SPECTROMETRY, AND CALCIUM AND MAGNESIUM BY ATOMIC-ABSORPTION SPECTROPHOTOMETRY [J].
FERREIRA, AMR ;
RANGEL, AOSS ;
LIMA, JLFC .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1995, 26 (1-2) :183-195
[9]   FLOW-INJECTION SIMULTANEOUS DETERMINATION OF BASIC CATION PAIRS IN SOILS [J].
FERREIRA, AMR ;
LIMA, JLFC ;
RANGEL, AOSS .
SOIL SCIENCE, 1995, 159 (05) :331-336
[10]   PROPERTIES OF A PHOSPHATIDYLCHOLINE DERIVATIVE OF DIPHENYL HEXATRIENE (DPH-PC) IN LYMPHOCYTE MEMBRANES - A COMPARISON WITH DPH AND THE CATIONIC DERIVATIVE TMA-DPH USING STATIC AND DYNAMIC FLUORESCENCE [J].
FERRETTI, G ;
TANGORRA, A ;
ZOLESE, G ;
CURATOLA, G .
MEMBRANE BIOCHEMISTRY, 1993, 10 (01) :17-27