Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

被引:36
作者
Mongioj, V
Brusa, A
Loi, G
Pignoli, E
Gramaglia, A
Scorsetti, M
Bombardieri, E
Marchesini, R
机构
[1] Ist Nazl Tumori, Div Hlth Phys, I-20133 Milan, Italy
[2] Ist Nazl Tumori, Div Radiotherapy B, I-20133 Milan, Italy
[3] Ist Nazl Tumori, Div Nucl Med, I-20133 Milan, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 01期
关键词
single photon emission tomography; computed tomography; magnetic resonance; image registration; image fusion;
D O I
10.1016/S0360-3016(98)00363-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and Tc-99m for SPECT), The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient, Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Delta x was less than or equal to 0.9 mm for MR and less than or equal to 1.4 mm for SPECT, by was less than or equal to 1 mm and less than or equal to 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT), In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning, (C) 1998 Elsevier Science Inc.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 16 条
  • [1] SPET IMAGING OF INTRACRANIAL TUMORS WITH TC-99(M)-SESTAMIBI
    BAGNI, B
    PINNA, L
    TAMAROZZI, R
    CATTARUZZI, E
    MARZOLA, MC
    BAGNI, I
    CERUTI, S
    VALENTINI, A
    ZANASI, A
    MAVILLA, L
    GUERRA, PU
    MERLI, AG
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1995, 16 (04) : 258 - 264
  • [2] ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY
    EVANS, AC
    BEIL, C
    MARRETT, S
    THOMPSON, CJ
    HAKIM, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) : 513 - 530
  • [3] INTEGRATION OF MULTIMODALITY IMAGING DATA FOR RADIOTHERAPY TREATMENT PLANNING
    KESSLER, ML
    PITLUCK, S
    PETTI, P
    CASTRO, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06): : 1653 - 1667
  • [4] IMAGE FUSION FOR STEREOTAXIC RADIOTHERAPY AND RADIOSURGERY TREATMENT PLANNING
    KOOY, HM
    VANHERK, M
    BARNES, PD
    ALEXANDER, E
    DUNBAR, SF
    TARBELL, NJ
    MULKERN, RV
    HOLUPKA, EJ
    LOEFFLER, JS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1229 - 1234
  • [5] LEKSELL L, 1951, ACTA CHIR SCAND, V102, P316
  • [6] LORCAN A, 1993, J NUCL MED, V34, P1045
  • [7] MINOSHIMA S, 1993, J NUCL MED, V34, P322
  • [8] ANATOMICAL ADJUSTMENTS IN BRAIN POSITRON EMISSION TOMOGRAPHY USING CT IMAGES
    MIURA, S
    KANNO, I
    IIDA, H
    MURAKAMI, M
    TAKAHASHI, K
    SASAKI, H
    INUGAMI, A
    SHISHIDO, F
    OGAWA, T
    UEMURA, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 363 - 367
  • [9] ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN
    PELIZZARI, CA
    CHEN, GTY
    SPELBRING, DR
    WEICHSELBAUM, RR
    CHEN, CT
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) : 20 - 26
  • [10] PELIZZARI CA, 1994, ICRU NEWS JUN, P4