Balloon-artery interactions during stent placement - A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury

被引:177
作者
Rogers, C
Tseng, DY
Squire, JC
Edelman, ER
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med,Div Cardiovasc, Cardiac Catheterizat Lab, Boston, MA 02115 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med,Div Cardiovasc, Coronary Care Unit, Boston, MA 02115 USA
[3] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
stent; restenosis; vascular injury; balloon; finite element analysis;
D O I
10.1161/01.RES.84.4.378
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Endovascular stents expand the arterial lumen more than balloon angioplasty and reduce rates of restenosis after coronary angioplasty in selected patients. Understanding the factors involved in vascular injury imposed during stent deployment may allow optimization of stent design and stent-placement protocols so as to limit vascular injury and perhaps reduce restenosis. Addressing the hypothesis that a previously undescribed mechanism of vascular injury during stent deployment is balloon-artery interaction, we have used finite element analysis to model how balloon-artery contact stress and area depend on stent-strut geometry, balloon compliance, and inflation pressure. We also examined superficial injury during deployment of stents of varied design in vivo and in a phantom model ex vivo to show that balloon-induced damage can be modulated by altering stent design. Our results show that higher inflation pressures, wider stent-strut openings, and more compliant balloon materials cause markedly larger surface-contact areas and contact stresses between stent struts. Appreciating that the contact stress and contact area are functions of placement pressure, stent geometry, and balloon compliance may help direct development of novel stent designs and stent-deployment protocols so as to minimize vascular injury during stenting and perhaps to optimize long-term outcomes.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 39 条
[1]  
Andersen HR, 1996, CIRCULATION, V93, P1716
[2]   Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries [J].
Barth, KH ;
Virmani, R ;
Froelich, J ;
Takeda, T ;
Lossef, SV ;
Newsome, J ;
Jones, R ;
Lindisch, D .
CIRCULATION, 1996, 93 (12) :2161-2169
[3]   A SOLUTION METHOD FOR PLANAR AND AXISYMMETRIC CONTACT PROBLEMS [J].
BATHE, KJ ;
CHAUDHARY, A .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 1985, 21 (01) :65-88
[4]  
BATHE KJ, 1996, FINITE ELEMENT PROCE
[5]  
BAUMGARTNER H R, 1970, Federation Proceedings, V29, P710
[7]   Induction of DNA synthesis by a single transient mechanical stimulus of human vascular smooth muscle cells - Role of fibroblast growth factor-2 [J].
Cheng, GC ;
Libby, P ;
Grodzinsky, AJ ;
Lee, RT .
CIRCULATION, 1996, 93 (01) :99-105
[8]  
CLOWES AW, 1989, LAB INVEST, V60, P360
[9]  
CLOWES AW, 1983, LAB INVEST, V49, P327
[10]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688