The development of iodine based impinger solutions for the efficient capture of Hg0 using direct injection nebulization -: Inductively coupled plasma mass spectrometry analysis

被引:16
作者
Hedrick, E
Lee, TG
Biswas, P
Zhuang, Y
机构
[1] US EPA, Natl Exposure Res Lab, Cincinnati, OH 45268 USA
[2] Univ Cincinnati, Cincinnati, OH 45221 USA
关键词
D O I
10.1021/es010648r
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Inductively coupled plasma mass spectrometry (ICP/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (H-g(0)) in EPA Method 5 type sampling. An iodine based impinger solution proved to be very efficient for H-g(0) capture and was amenable to direct analysis by DIN-ICP/MS. H-g(0) capture efficiency using aqueous iodine (I-3(-)) was comparable to H-g(0) capture using acidified potassium permanganate impinger solutions which were analyzed by cold vapor atomic absorption spectrometry (CVAAS), with greater than 98% capture of H-g(0) in the first oxidizing impinger. Using DIN-ICP/MS, it was demonstrated for the first time that iodine can be generated just prior to impinger sampling for efficiently oxidizing H-g(0) and retaining it in solution as HgI42-. Due to the increased interest in Hg speciation from combustion sources and the potential for using DIN-ICP/MS for multiple metals analyses, an impinger sampling train for gaseous Hg speciation and multiple metals analyses using DIN-ICP/MS analyses is presented. The unique feature of such a sampling train is that each impinger solution in the series is amenable to direct analysis by DIN-ICP/MS. A bituminous coal was combusted in a bench scale coal system, and gaseous Hg species (oxidized and elemental) were determined using the proposed impinger train. The DIN-ICP/MS instrumental detection limit was 0.003 ppb, and MDLs ranged from 0.007 to 0.116 mug/L (ppb) in a variety of impinger solutions used for Hg capture.
引用
收藏
页码:3764 / 3773
页数:10
相关论文
共 30 条
[1]  
[Anonymous], 2000, TOXICOLOGICAL EFFECT
[2]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[3]  
CHASE DL, 1972, APTD1174 USEPA
[4]  
EVANS AP, 1997, P 90 ANN M AIR WAST
[5]   METAL SPECIATION BY MEANS OF MICROBORE COLUMNS WITH DIRECT-INJECTION NEBULIZATION BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY [J].
GJERDE, DT ;
WIEDERIN, DR ;
SMITH, FG ;
MATTSON, BM .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :73-78
[6]   TRACE ANALYSES FOR WASTEWATERS [J].
GLASER, JA ;
FOERST, DL ;
MCKEE, GD ;
QUAVE, SA ;
BUDDE, WL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (12) :1426-1435
[7]   Cognitive performance of children prenatally exposed to "safe" levels of methylmercury [J].
Grandjean, P ;
Weihe, P ;
White, RF ;
Debes, F .
ENVIRONMENTAL RESEARCH, 1998, 77 (02) :165-172
[8]   FRONTIERS IN ELEMENTAL ANALYSIS BY MASS-SPECTROMETRY [J].
HOUK, RS ;
SHUM, SCK ;
WIEDERIN, DR .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :61-70
[9]   Oxidation chemistry of chloric acid in NOx/SOx and air toxic metal removal from gas streams [J].
Kaczur, JJ .
ENVIRONMENTAL PROGRESS, 1996, 15 (04) :245-254
[10]   ELEMENTAL SPECIATION VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COMBINED WITH INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROSCOPIC DETECTION - APPLICATION OF A DIRECT INJECTION NEBULIZER [J].
LAFRENIERE, KE ;
FASSEL, VA ;
ECKELS, DE .
ANALYTICAL CHEMISTRY, 1987, 59 (06) :879-887