Fluid balance and weaning outcomes

被引:152
作者
Upadya, A
Tilluckdharry, L
Muralidharan, V
Amoateng-Adjepong, Y
Manthous, CA
机构
[1] Bridgeport Hosp, Bridgeport, CT 06610 USA
[2] Yale Univ, Sch Med, Bridgeport, CT 06610 USA
关键词
weaning; extubation; mechanical ventilation; fluid; resuscitation;
D O I
10.1007/s00134-005-2801-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To examine the relationship of fluid balance and weaning outcomes. Methods: We prospectively collected demographic, physiological, daily fluid balance (measured inputs minus outputs), and weaning data from 87 mechanically ventilated patients. Patients: We examined 87 patients, a median age of 66 years, APACHE II of 22, and performed 205 breathing trials (BT); 38 patients (44%) were successfully extubated after their first BT with minimal or no pressure support. Results: Positive fluid balance (inputs > outputs) in the 24, 48, and 72 h and cumulatively (from hospital admission) prior to weaning were significantly greater in weaning failures than successes. Both univariate and multivariate analyses, adjusted for duration of mechanical ventilation and presence of chronic obstructive pulmonary disease, showed negative cumulative fluid balance 24 h prior to BTs (OR=2.9) and cumulative fluid balance (OR=3.4) to be independently associated with first-day weaning success. Similar relationships were demonstrated when all weaning attempts were analyzed. Negative fluid balance was as predictive of weaning outcomes as f/V-t (likelihood of success was 1.7 for patients with negative fluid balance 24 h prior to weaning and 1.2 for those with f/V-t < 100 min(-1) l(-1)). Although administration of diuretics was associated with more negative fluid balance, it was not independently associated with weaning outcomes. Conclusions: These data suggest that fluid balance, a potentially modifiable factor, is associated with weaning outcomes. A randomized study is required to determine whether diuresis to treat positive fluid balance expedites liberation from mechanical ventilation.
引用
收藏
页码:1643 / 1647
页数:5
相关论文
共 17 条
[1]   Negative fluid balance predicts survival in patients with septic shock - A retrospective pilot study [J].
Alsous, F ;
Khamiees, M ;
DeGirolamo, A ;
Amoateng-Adjepong, Y ;
Manthous, CA .
CHEST, 2000, 117 (06) :1749-1754
[2]   Variables predicting reintubation after cardiac surgical procedures [J].
Engoren, M ;
Buderer, NF ;
Zacharias, A ;
Habib, RH .
ANNALS OF THORACIC SURGERY, 1999, 67 (03) :661-665
[3]  
EPSTEIN CD, 2003, AM J CRIT CARE, V13, P273
[4]  
Epstein S K, 2000, Respir Care Clin N Am, V6, P253, DOI 10.1016/S1078-5337(05)70070-8
[5]   LIFE-THREATENING HYPOTENSION ASSOCIATED WITH EMERGENCY INTUBATION AND THE INITIATION OF MECHANICAL VENTILATION [J].
FRANKLIN, C ;
SAMUEL, J ;
HU, TC .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1994, 12 (04) :425-428
[6]  
Hosmer W., 2000, Applied Logistic Regression, VSecond
[7]   Predictors of extubation outcome in patients who have successfully completed a spontaneous breathing trial [J].
Khamiees, M ;
Raju, P ;
DeGirolamo, A ;
Amoateng-Adjepong, Y ;
Manthous, CA .
CHEST, 2001, 120 (04) :1262-1270
[8]  
Khamiees Mohammad, 2002, Respir Care, V47, P150
[9]   Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation [J].
Kress, JP ;
Pohlman, AS ;
O'Connor, MF ;
Hall, JB .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (20) :1471-1477
[10]   ACUTE LEFT-VENTRICULAR DYSFUNCTION DURING UNSUCCESSFUL WEANING FROM MECHANICAL VENTILATION [J].
LEMAIRE, F ;
TEBOUL, JL ;
CINOTTI, L ;
GIOTTO, G ;
ABROUK, F ;
STEG, G ;
MACQUINMAVIER, I ;
ZAPOL, WM .
ANESTHESIOLOGY, 1988, 69 (02) :171-179