Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar

被引:97
作者
Cook, Jackie [1 ,2 ]
Aydin-Schmidt, Berit [1 ]
Gonzalez, Iveth J. [3 ]
Bell, David [4 ]
Edlund, Elin [1 ]
Nassor, Majda H. [5 ]
Msellem, Mwinyi [5 ]
Ali, Abdullah [5 ]
Abass, Ali K. [5 ]
Martensson, Andreas [1 ,6 ,7 ]
Bjorkman, Anders [1 ]
机构
[1] Karolinska Inst, Dept Microbiol Tumor & Cell Biol, SE-17177 Stockholm, Sweden
[2] London Sch Hyg & Trop Med, Dept Immunol & Infect, London WC1, England
[3] Fdn Innovat New Diagnost, Geneva, Switzerland
[4] Global Good Intellectual Ventures Lab, Bellevue, WA USA
[5] Minist Hlth, Zanzibar Malaria Eliminat Programme, Zanzibar, Tanzania
[6] Karolinska Inst, Dept Publ Hlth Sci, Global Hlth IHCAR, SE-17177 Stockholm, Sweden
[7] Uppsala Univ, Ctr Clin Res Sormland, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
LAMP; Low-density; Malaria; Zanzibar; Elimination; Asymptomatic; Diagnostics; PCR; PERFORMANCE; ASSAY;
D O I
10.1186/s12936-015-0573-y
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Asymptomatic, low parasite density malaria infections are difficult to detect with currently available point-of-care diagnostics. This study piloted a loop-mediated isothermal amplification (LAMP) kit for field-friendly, high-throughput detection of asymptomatic malaria infections during mass screening and treatment (MSAT) in Zanzibar, a malaria pre-elimination setting. Methods: Screening took place in three known hotspot areas prior to the short rains in November. Finger-prick blood was taken for screening by rapid diagnostic test (RDT) and LAMP and collected on filter paper for subsequent polymerase chain reaction (PCR) analyses. LAMP results were compared to RDT and to PCR using McNemar's test. Results: Approximately 1,000 people were screened. RDT detected ten infections (1.0% (95% CI 0.3-1.6)) whilst both LAMP and PCR detected 18 (1.8% (95% CI 0.9-2.6)) infections. However, PCR identified three infections that LAMP did not detect and vice versa. LAMP testing was easy to scale-up in field conditions requiring minimal training and equipment, with results ready one to three hours after screening. Conclusions: Despite lower than expected prevalence, LAMP detected a higher number of infections than the currently used diagnostic, RDT. LAMP is a field-friendly, sensitive diagnostic test that could be useful for MSAT malaria campaigns which require quick results to enable prompt treatment.
引用
收藏
页数:6
相关论文
共 18 条
[1]   Comparative evaluation of published real-time PCR assays for the detection of malaria following MIQE guidelines [J].
Alemayehu, Saba ;
Feghali, Karla C. ;
Cowden, Jessica ;
Komisar, Jack ;
Ockenhouse, Christian F. ;
Kamau, Edwin .
MALARIA JOURNAL, 2013, 12
[2]  
[Anonymous], J INFECT DIS
[3]   Loop Mediated Isothermal Amplification (LAMP) Accurately Detects Malaria DNA from Filter Paper Blood Samples of Low Density Parasitaemias [J].
Aydin-Schmidt, Berit ;
Xu, Weiping ;
Gonzalez, Iveth J. ;
Polley, Spencer D. ;
Bell, David ;
Shakely, Deler ;
Msellem, Mwinyi I. ;
Bjorkman, Anders ;
Martensson, Andreas .
PLOS ONE, 2014, 9 (08)
[4]   Plasmodium falciparum gametocyte carriage in asymptomatic children in western Kenya -: art. no. 18 [J].
Bousema, JT ;
Gouagna, LC ;
Drakeley, CJ ;
Meutstege, AM ;
Okech, BA ;
Akim, INJ ;
Beier, JC ;
Githure, JI ;
Sauerwein, RW .
MALARIA JOURNAL, 2004, 3 (1)
[5]   The changing epidemiology of malaria elimination: new strategies for new challenges [J].
Cotter, Chris ;
Sturrock, Hugh J. W. ;
Hsiang, Michelle S. ;
Liu, Jenny ;
Phillips, Allison A. ;
Hwang, Jimee ;
Gueye, Cara Smith ;
Fullman, Nancy ;
Gosling, Roly D. ;
Feachem, Richard G. A. .
LANCET, 2013, 382 (9895) :900-911
[6]   Performance of microscopy and RDTs in the context of a malaria prevalence survey in Angola: a comparison using PCR as the gold standard [J].
Fancony, Claudia ;
Sebastiao, Yuri V. ;
Pires, Joao E. ;
Gamboa, Dina ;
Nery, Susana V. .
MALARIA JOURNAL, 2013, 12
[7]  
FIND, MAN STAND OP PROC MA
[8]  
Hartung C., 2010, P 4 ACM IEEE INT C I, P1, DOI DOI 10.1145/2369220.2369236
[9]   Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda [J].
Hopkins, Heidi ;
Gonzalez, Iveth J. ;
Polley, Spencer D. ;
Angutoko, Patrick ;
Ategeka, John ;
Asiimwe, Caroline ;
Agaba, Bosco ;
Kyabayinze, Daniel J. ;
Sutherland, Colin J. ;
Perkins, Mark D. ;
Bell, David .
JOURNAL OF INFECTIOUS DISEASES, 2013, 208 (04) :645-652
[10]   Sample-ready multiplex qPCR assay for detection of malaria [J].
Kamau, Edwin ;
Alemayehu, Saba ;
Feghali, Karla C. ;
Juma, Dennis W. ;
Blackstone, George M. ;
Marion, William R. ;
Obare, Peter ;
Ogutu, Bernhards ;
Ockenhouse, Christian F. .
MALARIA JOURNAL, 2014, 13