Measuring visual acuity: theoretical foundations and computer-assisted instrumentation

被引:98
作者
Bach, M [1 ]
Kommerell, G [1 ]
机构
[1] Univ Freiburg, Augenklin, Abt Neuroophthalmol, D-79106 Freiburg, Germany
关键词
visual acuity; psychometric function; threshold estimation; computer;
D O I
10.1055/s-2008-1034863
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Psychometric function According to the European standard EN ISO 8596 the Landolt-C in 8 different orientations has to be used to measure visual acuity. With decreasing size of the Landolt-C the hit rate declines from 100% to the chance level of 12.5%. This gradual transition is described by the "psychometric function". The steepest point of the psychometric function is in the middle between 100 and 12.5, i.e., at 56.25%. This point of the psychometric function (approximated by 5 of 8 Landolt-Cs) has been selected as the threshold for visual acuity, because it is there that the visual acuity is influenced least by (incidental) fluctuations. The subject has to answer by forced choice; a response like "I cannot detect anything" is not acceptable. "Normal" visual acuity cannot be assigned to a certain value, like 1.0 or 6/6. With the standard test procedure, visually healthy, young subjects achieve a visual acuity of about 2.0 or 12/6, while in senior subjects 0,5 (3/6) may be "normal". Averaging visual acuity Logarithmic, not arithmetic, scaling of visual acuity approximates the perceptual metric. Consequently, visual acuity values may not be averaged arithmetically. Instead, three steps are required: all values have to be converted to logarithms, then averaged, and finally the average can be reconverted. Geometric average is equivalent. "Minimum Angle of Resolution" not necessary MAR is the reciprocal of visual acuity. In many studies, clinical outcome has been assessed using log(MAR). Though statistically correct, this term is unnecessary, as log(acuity) has identical statistical properties. Furthermore, log(MAR) is contra-intuitive as its value becomes smaller when vision improves. Computer-assisted instrumentation facilitates complying with the EN ISO 8596. For instance, the Freiburg Visual Acuity Test relieves the examiner from observing whether 5 responses have been correct, and that not more than 8 tests are given per level.
引用
收藏
页码:190 / 195
页数:8
相关论文
共 33 条
[1]  
Aulhorn E, 1970, Klin Monbl Augenheilkd, V157, P843
[2]   Raster-scan cathode-ray tubes for vision research - Limits of resolution in space, time and intensity, and some solutions [J].
Bach, M ;
Meigen, T ;
Strasburger, H .
SPATIAL VISION, 1997, 10 (04) :403-414
[3]   The Freiburg Visual Acuity test - Automatic measurement of visual acuity [J].
Bach, M .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :49-53
[4]   Anti-aliasing and dithering in the 'Freiburg Visual Acuity Test' [J].
Bach, M .
SPATIAL VISION, 1997, 11 (01) :85-89
[5]  
Bach M., 1995, Ophthalmologe, V92, P174
[6]  
*CEN EUR KOM NORM, 1996, 8596 CEN EN ISO EUR
[7]  
CROSSMAN RF, 1970, AMER J OPT ARCH AM A, V47, P344
[8]  
DIEPES H, 1990, OPTOMETRIE, V1, P3
[9]   AUTOMATED MEASUREMENT OF FAR VISION BASED ON THE DIN STANDARD [J].
EFFERT, R ;
STEINMETZ, H ;
JANSEN, W ;
RAU, G ;
REIM, M .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1989, 195 (01) :39-43
[10]  
ETTELT B, 1991, FORTSCHR OPHTHALMOL, V88, P59