Ultrasound echo is related to stress and strain in tendon

被引:38
作者
Duenwald, Sarah [1 ]
Kobayashi, Hirohito [3 ]
Frisch, Kayt [1 ]
Lakes, Roderic [1 ,2 ]
Vanderby, Ray, Jr. [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Engn Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Orthoped, Madison, WI 53792 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Tendon; Ultrasound; Echo intensity; Acoustoelasticity; HYPER-ELASTIC MATERIALS; VIVO HUMAN TENDON; MECHANICAL-PROPERTIES; IN-VIVO; VISCOELASTIC PROPERTIES; ACOUSTOELASTIC ANALYSIS; ELASTOGRAPHY; TISSUE; VITRO; DISPLACEMENT;
D O I
10.1016/j.jbiomech.2010.09.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The mechanical behavior of tendons has been well studied in vitro. A noninvasive method to acquire mechanical data would be highly beneficial. Elastography has been a promising method of gathering in vivo tissue mechanical behavior, but it has inherent limitations. This study presents acoustoelasticity as an alternative ultrasound-based method of measuring tendon stress and strain by reporting a relationship between ultrasonic echo intensity (B-mode ultrasound image brightness) and mechanical behavior of tendon in vitro. Porcine digital flexor tendons were cyclically loaded in a mechanical testing system while an ultrasonic echo response was recorded. We report that echo intensity closely follows the applied cyclic strain pattern in time with higher strain protocols resulting in larger echo intensity changes. We also report that echo intensity is related nonlinearly to stress and nearly linearly to strain. This indicates that ultrasonic echo intensity is related to the mechanical behavior in a loaded tissue by an acoustoelastic response, as previously described in homogeneous, nearly incompressible materials. Acoustoelasticity is therefore able to relate strain-dependent stiffness and stress to the reflected echo, even in the processed B-mode signals reflected from viscoelastic and inhomogeneous material such as tendon, and is a promising metric to acquire in vivo mechanical data noninvasively. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:424 / 429
页数:6
相关论文
共 30 条
[1]
MECHANICAL BEHAVIOUR OF TENDON IN VITRO - A PRELIMINARY REPORT [J].
ABRAHAMS, M .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (05) :433-+
[2]
A COMPUTATIONAL FRAMEWORK AND AN ALGORITHM FOR THE MEASUREMENT OF VISUAL-MOTION [J].
ANANDAN, P .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1989, 2 (03) :283-310
[3]
PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[4]
VISCOELASTIC CREEP OF COLLAGENOUS TISSUE [J].
COHEN, RE ;
HOOLEY, CJ ;
MCCRUM, NG .
JOURNAL OF BIOMECHANICS, 1976, 9 (04) :175-184
[5]
Correlations between mean echogenicity and material properties of normal and diseased equine superficial digital flexor tendons: an in vitro segmental approach [J].
Crevier-Denoix, N ;
Ruel, Y ;
Dardillat, C ;
Jerbi, H ;
Sanaa, M ;
Collobert-Laugier, C ;
Ribot, X ;
Denoix, JM ;
Pourcelot, P .
JOURNAL OF BIOMECHANICS, 2005, 38 (11) :2212-2220
[6]
Real-Time Sonoelastography of Lateral Epicondylitis: Comparison of Findings Between Patients and Healthy Volunteers [J].
De Zordo, Tobias ;
Lill, Stephanie R. ;
Fink, Christian ;
Feuchtner, Gudrun M. ;
Jaschke, Werner ;
Bellmann-Weiler, Rosa ;
Klauser, Andrea S. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) :180-185
[7]
Evaluation of an iterative reconstruction method for quantitative elastography [J].
Doyley, MM ;
Meaney, PM ;
Bamber, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1521-1540
[8]
REGION-BASED ENDOCARDIUM TRACKING ON REAL-TIME THREE-DIMENSIONAL ULTRASOUND [J].
Duan, Qi ;
Angelini, Elsad D. ;
Herz, Susan L. ;
Ingrassia, Christopher M. ;
Costa, Kevin D. ;
Holmes, Jeffrey W. ;
Homma, Shunichi ;
Laine, Andrew F. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (02) :256-265
[9]
2ND-ORDER ELASTIC DEFORMATION OF SOLIDS [J].
HUGHES, DS ;
KELLY, JL .
PHYSICAL REVIEW, 1953, 92 (05) :1145-1149
[10]
Breast disease: Clinical application of US elastography for diagnosis [J].
Itoh, A ;
Ueno, E ;
Tohno, E ;
Kamma, H ;
Takahashi, H ;
Shiina, T ;
Yamakawa, M ;
Matsumura, T .
RADIOLOGY, 2006, 239 (02) :341-350