A photoacoustic trace-gas sensor for the measurement of nitric oxide with a detection limit of 500 parts in 109 has been demonstrated. The radiation source was a thermoelectrically cooled distributed-feedback quantum-cascade laser operating in pulsed mode near 5.3 mu m with an average laser power of 8 mW. A resonant photoacoustic cell was excited in its first longitudinal mode by the modulated laser light. Preliminary measurements have been performed to test the performance of our photoacoustic sensor; possible improvements to reach lower detection limits are discussed. (c) 2005 Optical Society of America
引用
收藏
页码:988 / 990
页数:3
相关论文
共 11 条
[1]  
ALVING K, 1993, EUR RESPIR J, V6, P1368
[2]   Geometrical optimization of a longitudinal resonant photoacoustic cell for sensitive and fast trace gas detection [J].
Bijnen, FGC ;
Reuss, J ;
Harren, FJM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08) :2914-2923
[3]   Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers [J].
Hofstetter, D ;
Beck, M ;
Faist, J ;
Nägele, M ;
Sigrist, MW .
OPTICS LETTERS, 2001, 26 (12) :887-889
[4]   Chemical sensors based on quantum cascade lasers [J].
Kosterev, AA ;
Tittel, FK .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2002, 38 (06) :582-591
[5]   Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser [J].
Kosterev, AA ;
Malinovsky, AL ;
Tittel, FK ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY .
APPLIED OPTICS, 2001, 40 (30) :5522-5529
[6]   Spectroscopic detection of biological NO with a quantum cascade laser [J].
Menzel, L ;
Kosterev, AA ;
Curl, RF ;
Tittel, FK ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY ;
Urban, W .
APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (07) :859-863
[7]   Sub-part-per-billion detection of nitric oxide in air using a thermoelectrically cooled mid-infrared quantum cascade laser spectrometer [J].
Nelson, DD ;
Shorter, JH ;
McManus, JB ;
Zahniser, MS .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3) :343-350
[8]   Photoacoustic spectroscopy using quantum-cascade lasers [J].
Paldus, BA ;
Spence, TG ;
Zare, RN ;
Oomens, J ;
Harren, FJM ;
Parker, DH ;
Gmachl, C ;
Cappasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY .
OPTICS LETTERS, 1999, 24 (03) :178-180
[9]  
Seinfeld J.H., 2016, ATMOS CHEM PHYS
[10]  
Sigrist M. W, 1994, Air Moni. Spectros. Tech, P163