Uniformly sized molecularly imprinted polymer for atropine and its application to the determination of atropine and scopolamine in pharmaceutical preparations containing scopolia extract

被引:35
作者
Nakamura, M
Ono, M
Nakajima, T
Ito, Y
Aketo, T
Haginaka, J
机构
[1] Taisho Pharmaceut Co Ltd, Analyt Lab, Selfmedicat Labs, Kita Ku, Saitama, Saitama 3319530, Japan
[2] Mukogawa Womens Univ, Fac Pharmaceut Sci, Nishinomiya, Hyogo 6638179, Japan
关键词
molecularly imprinted polymer; atropine; scopolamine; scopolia extract; column switching; pharmaceutical analysis;
D O I
10.1016/j.jpba.2004.10.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A uniformly sized molecularly imprinted polymer (MIP) for atropine has been prepared. The MIP was prepared using 2-(trifluoromethyl) acrylic acid and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and thermal polymerization method. The selectivity factor, which is defined as the ratio of the retention factors (k) on the molecularly imprinted and non-imprinted polymers, k(imprinted)/k(non-imprinted), was 2.2 for atropine on the MIP. The obtained MIP was applied for the determination of tropane alkaloids (atropine and scopolamine) in a commercial gastrointestinal drug by a column-switching HPLC system, consisting of all MIP material as a pre-column. and a conventional cation-exchange analytical column. An interference peak was observed at the retention time of atropine derived from pre-column. However, since the peak area was less than 0.5% the peak area of atropine of a standard solution under the analytical conditions of this study (0.2 mug of atropine was loaded), this interference was negligible in the determination of atropine. On the other hand, no interference peak was observed at the retention time of scopolamine. Calibration curves of atropine and scopolamine showed food linearity in the range of 0.02-0.9 mug/ml (r = 0.9999) and 0.003-0.09 mug/ml (r = 0.9998), respectively. The mean recoveries of atropine and scopolamine from a placebo pharmaceutical preparation sample were 98.9 and 99.9%, respectively. The intra-day precision (measured by relative standard deviation, R.S.D. (%)) of both ingredients was less than 2.0%. The optimized column-switching system was applied successfully to the determination of atropine and scopolamine in a commercial gastrointestinal drug. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 24 条
[1]   Investigation of the effect of space environment on the contents of atropine and scopolamine in Datura metel by capillary zone electrophoresis [J].
Bo, T ;
Li, KA ;
Liu, HW .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) :885-891
[2]   Analysis of tropane and related alkaloids [J].
Dräger, B .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :1-35
[3]   On-line selective solid-phase extraction of 4-nitrophenol with β-cyclodextrin bonded silica [J].
Fan, Y ;
Feng, YQ ;
Da, SL .
ANALYTICA CHIMICA ACTA, 2003, 484 (02) :145-153
[4]   SIMULTANEOUS ANALYSIS OF L-HYOSCYAMINE, L-SCOPOLAMINE AND DL-TROPIC ACID IN PLANT-MATERIAL BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FLINIAUX, MA ;
MANCEAU, F ;
JACQUINDUBREUIL, A .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :193-197
[5]   Uniform-sized molecularly imprinted polymers for 2-arylpropionic acid derivatives selectively modified with hydrophilic external layer and their applications to direct serum injection analysis [J].
Haginaka, J ;
Sanbe, H .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5206-5210
[6]   Uniformly sized molecularly imprinted polymer for d-chlorpheniramine -: Evaluation of retention and molecular recognition properties in an aqueous mobile phase [J].
Haginaka, J ;
Kagawa, C .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :77-84
[7]   Retentivity and enantioselectivity of uniformly sized molecularly imprinted polymers for d-chlorpheniramine and -brompheniramine in hydro-organic mobile phases [J].
Haginaka, J ;
Kagawa, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :19-24
[8]   Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography [J].
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :3-54
[9]   Molecularly imprinted uniform-size polymer-based stationary phase for high-performance liquid chromatography - Structural contribution of cross-linked polymer network on specific molecular recognition [J].
Hosoya, K ;
Yoshizako, K ;
Shirasu, Y ;
Kimata, K ;
Araki, T ;
Tanaka, N ;
Haginaka, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :139-147
[10]   UNIFORM-SIZE MACROPOROUS POLYMER-BASED STATIONARY-PHASE FOR HPLC PREPARED THROUGH MOLECULAR IMPRINTING TECHNIQUE [J].
HOSOYA, K ;
YOSHIZAKO, K ;
TANAKA, N ;
KIMATA, K ;
ARAKI, T ;
HAGINAKA, J .
CHEMISTRY LETTERS, 1994, (08) :1437-1438