Safety assessment of gadoversetamide (OptiMARK®) administered by power injector

被引:7
作者
Abdou, N
Napoli, AM
Hynes, MR
Allen, JC
Wible, JH
机构
[1] Tyco Healthcare Mallinckrodt Imaging, Biol & Clin Sci, St Louis, MO 63134 USA
[2] Quintiles Phase 1 Serv, Lenexa, KS USA
关键词
OptiMARK (R); gadoversetamide; magnetic resonance imaging (MRI); contrast enhancement; gadolinium (Gd); power injection; injection rate; safety;
D O I
10.1002/jmri.10439
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the safety of OptiMARK(R) (gadoversetamide injection) administered via power injector. Materials and Methods: The study population included 144 healthy volunteers aged 18 years or older randomly assigned to one of seven treatment groups (N = 20/group). The safety assessment was based on changes in physical examination, vital signs, electrocardiograms (ECGs), standard clinical laboratory tests, and adverse events (AEs) through a 24-hour postinjection period. Results: OptiMARK caused no serious AEs or unexpected changes in physical examinations or laboratory parameters. The changes observed in vital signs and ECG intervals did not vary with changes in injection rate and were not significantly (P < 0.05) different from those elicited by saline administration at the same rates. Conclusion: This study demonstrated the safety of OptiMARK when administered via a power injector at rates of 2, 4, and 6 mL/second.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 9 条
[1]   Magnetic resonance imaging in patients with central nervous system pathology: A comparison of OptiMARK (Gd-DTPA-BMEA) and Magnevist (Gd-DTPA) [J].
Grossman, RI ;
Rubin, DL ;
Hunter, G ;
Haughton, VM ;
Lee, D ;
Sze, G ;
Kuhn, MJ ;
Maravilla, K ;
Tu, R ;
Heindel, W ;
Wippold, FJ ;
Leeds, N ;
Zelch, J ;
Jinkins, JR ;
Grodd, W ;
Truwit, C ;
Kanal, E ;
Provenzale, JM ;
Ramsey, R ;
Simon, J ;
Brunberg, JA ;
Stevens, GR ;
Kristy, RM .
INVESTIGATIVE RADIOLOGY, 2000, 35 (07) :412-419
[2]  
Rubin DL, 1999, JMRI-J MAGN RESON IM, V9, P240, DOI 10.1002/(SICI)1522-2586(199902)9:2<240::AID-JMRI14>3.0.CO
[3]  
2-#
[4]   CONTRAST-ENHANCED 3-DIMENSIONAL MR-ANGIOGRAPHY IN A SINGLE BREATH-HOLD - A NOVEL TECHNIQUE [J].
SHETTY, AN ;
SHIRKHODA, A ;
BIS, KG ;
ALCANTARA, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1290-1292
[5]  
Swan SK, 1999, JMRI-J MAGN RESON IM, V9, P317, DOI 10.1002/(SICI)1522-2586(199902)9:2<317::AID-JMRI25>3.0.CO
[6]  
2-B
[7]   Long QT syndromes and torsade de pointes [J].
Viskin, S .
LANCET, 1999, 354 (9190) :1625-1633
[8]   Cardiovascular effects caused by rapid administration of gadoversetamide injection in anesthetized dogs [J].
Wible, JH ;
Galen, KP ;
Wojdyla, JK .
INVESTIGATIVE RADIOLOGY, 2001, 36 (05) :292-298
[9]  
1997, FED REG 0509