An automated new technique for scoring the rodent micronucleus assay: computerized image analysis of acridine orange supravitally stained peripheral blood cells

被引:14
作者
Asano, N
Katsuma, Y
Tamura, H
Higashikuni, N
Hayashi, M
机构
[1] Nitto Denko Corp, Toxicol Res Div, Ibaraki, Osaka 5678680, Japan
[2] Toyobo Co Ltd, Biochem Operat Dept, Kita Ku, Osaka 5308230, Japan
[3] Nippon Shinyaku Co Ltd, Res Labs, Dept Toxicol, Minami Ku, Kyoto 6018550, Japan
[4] Itoham Foods Inc, Gen Res Inst, Moriya, Ibaraki 3020104, Japan
[5] Natl Inst Hlth Sci, Div Genet & Mutagenesis, Setagaya Ku, Tokyo 1588501, Japan
关键词
automated micronucleus assay; image analysis; peripheral blood; acridine orange supravital staining;
D O I
10.1016/S0027-5107(98)00108-0
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We developed an automated image analysis system to obtain objective data for the rodent peripheral blood micronucleus assay with acridine orange (AO) supravital staining. The system was able to identify micronucleated reticulocytes (MNRETs) and to evaluate inhibition of bone marrow cell proliferation by measuring the reticular area of reticulocytes (RETs). We also developed automated equipment to produce homogeneous acridine orange-coated glass slides. This study was designed to compare automated scoring with manual scoring using 4 model clastogens and 2 mouse strains. The MNRET incidence induced by each clastogen was similar for automated and manual scoring, and there was good correlation (r = 0.92) between the methods. In addition, an index of bone marrow toxicity based on the reticular area of RETs was compared to the conventional index (% of polychromatic erythrocytes (PCE) to total erythrocytes; PCE ratio) and was similar. The results indicated that our technique for computer-assisted image analysis for the micronucleus assay with AO supravitally stained peripheral blood RETs was comparable to conventional microscopic scoring, and it was superior in objectivity and statistical power. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 21 条
[1]  
ANDRESE AP, 1986, ENVIRON MOL MUTAGEN, V8, P5
[2]  
ASANO N, 1992, MUTAT RES, V278, P153
[3]   Flow cytometric analysis of micronucleated reticulocytes in mouse bone marrow [J].
Dertinger, SD ;
Torous, DK ;
Tometsko, KR .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 1997, 390 (03) :257-262
[4]   Quantitative and qualitative studies of micronucleus induction in mouse erythrocytes using flow cytometry .1. Measurement of micronucleus induction in peripheral blood polychromatic erythrocytes by chemicals with known and suspected genotoxicity [J].
Grawe, J ;
Nusse, M ;
Adler, ID .
MUTAGENESIS, 1997, 12 (01) :1-8
[5]  
HATAKEYAMA Y, 1992, MUTAT RES, V278, P193
[6]  
HAYASHI M, 1992, MUTAT RES, V278, P83
[7]   THE MICRONUCLEUS ASSAY WITH MOUSE PERIPHERAL-BLOOD RETICULOCYTES USING ACRIDINE ORANGE-COATED SLIDES [J].
HAYASHI, M ;
MORITA, T ;
KODAMA, Y ;
SOFUNI, T ;
ISHIDATE, M .
MUTATION RESEARCH, 1990, 245 (04) :245-249
[8]   FLOW CYTOMETRIC MICRONUCLEUS TEST WITH MOUSE PERIPHERAL ERYTHROCYTES [J].
HAYASHI, M ;
NORPPA, H ;
SOFUNI, T ;
ISHIDATE, M .
MUTAGENESIS, 1992, 7 (04) :257-264
[9]   MOUSE BONE-MARROW MICRONUCLEUS TEST USING FLOW-CYTOMETRY [J].
HAYASHI, M ;
NORPPA, H ;
SOFUNI, T ;
ISHIDATE, M .
MUTAGENESIS, 1992, 7 (04) :251-256
[10]   RAPID DETECTION OF MUTAGEN INDUCED MICRO-NUCLEATED ERYTHROCYTES BY FLOW-CYTOMETRY [J].
HUTTER, KJ ;
STOHR, M .
HISTOCHEMISTRY, 1982, 75 (03) :353-362