Avascular necrosis of the femoral head: inter- and intraobserver variations of Ficat and ARCO classifications

被引:126
作者
Schmitt-Sody, Marcus [1 ]
Kirchhoff, Chlodwig [2 ]
Mayer, Wolfgang [1 ]
Goebel, Michael [3 ]
Jansson, Volkmar [1 ]
机构
[1] Univ Hosp Grosshadern, Dept Orthoped Surg, D-81377 Munich, Germany
[2] Univ Hosp Innenstadt, Dept Orthoped Surg & Traumatol, D-80336 Munich, Germany
[3] Bogenhausen Hosp, Dept Orthoped Surg, D-81925 Munich, Germany
关键词
D O I
10.1007/s00264-007-0320-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Diagnosis of avascular necrosis (AVN) of the femoral head depends on the combination of clinical symptoms and evaluation of radiographs and/or magnetic resonance imaging (MRI). To evaluate the evolution of AVN, the Ficat and the Association Research Circulation Osseous (ARCO) classification are commonly used to assess both imaging modalities. For comparison reasons, these classifications need to be reliable and reproducible to provide sufficient therapy options for the patient. Therefore, the aim of our study was to evaluate the interobserver reliability and the intraobserver reproducibility of these classifications. Patients with suspected AVN were examined using either radiographs or radiographs and MRI. The radiographs and/or MR images were reviewed initially and at 3 months by two general orthopaedic surgeons, two orthopaedic residents, and two general radiologists using the Ficat classification for radiographs and MR images as well as the ARCO classification for MR images only. In all, 38 patients (54 hips) were enrolled. There were 10 patients who presented with radiographs and 28 patients with radiographs and MR scans. Paired comparisons revealed a mean interobserver kappa reliability coefficient of 0.39 for the first and of 0.32 for the second review using the Ficat classification for radiographs, whereas for the MR images a mean of 0.39 in the first and of 0.34 in the second reading resulted. The MRI evaluation using the ARCO classification resulted in a mean interobserver reliability coefficient of 0.37 in the first and of 0.31 in the second reading. The mean kappa value for intraobserver reproducibility using the Ficat classification was 0.52 for radiographs and 0.50 for MR images, whereas a reproducibility of 0.43 resulted for the ARCO classification. This study showed poor interobserver reliability and fair intraobserver variability, diminishing any meaningful comparison of studies using the Ficat as well as the ARCO classification. Thus, the Ficat and ARCO staging systems are still not sufficient to reliably assess the status of AVN alone.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 20 条
[1]
AARON RK, 1989, CLIN ORTHOP RELAT R, V249, P209
[2]
EVANS CLASSIFICATION OF TROCHANTERIC FRACTURES - AN ASSESSMENT OF THE INTEROBSERVER AND INTRAOBSERVER RELIABILITY [J].
ANDERSEN, E ;
JORGENSEN, LG ;
HEDEDAM, LT .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06) :377-378
[3]
Catto M, 1965, J Bone Joint Surg Br, V47, P749
[4]
IDIOPATHIC BONE NECROSIS OF THE FEMORAL-HEAD - EARLY DIAGNOSIS AND TREATMENT [J].
FICAT, RP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (01) :3-9
[5]
FRANDSEN PA, 1988, J BONE JOINT SURG, V70, P1048
[6]
Gardeniers JW, 1992, J JPN ORTHOP ASS, V66, P18
[7]
BONE-MARROW EDEMA SYNDROME AND TRANSIENT OSTEOPOROSIS OF THE HIP - AN MRI-CONTROLLED STUDY OF TREATMENT BY CORE DECOMPRESSION [J].
HOFMANN, S ;
ENGEL, A ;
NEUHOLD, A ;
LEDER, K ;
KRAMER, J ;
PLENK, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :210-216
[8]
JACOBS B, 1978, CLIN ORTHOP RELAT R, V277, P41
[9]
INTERTROCHANTERIC OSTEOTOMY FOR AVASCULAR NECROSIS OF THE FEMORAL-HEAD [J].
JACOBS, MA ;
HUNGERFORD, DS ;
KRACKOW, KA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02) :200-204
[10]
JONES JP, 1994, AAOS INSTR COURS LEC, V43, P499