Separation of enantiomers: needs, challenges, perspectives

被引:884
作者
Maier, NM [1 ]
Franco, P [1 ]
Lindner, W [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
关键词
reviews; enantiomer separation; chiral resolution; chiral selectors; membranes; enantioselective;
D O I
10.1016/S0021-9673(00)00532-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chiral drags, agrochemicals, food additives and fragrances represent classes of compounds with high economic and scientific potential. First the present implications of their chiral nature and necessity of separating enantiomers are summarised in this article. In the following a brief overview of the actual approaches to perform enantioseparations at analytical and preparative scale is given. Challenging aspects of these strategies, such as problems associated with data management, choice of suitable chiral selectors for given enantioseparations and enhanced understanding of the underlying chiral recognition principles, are discussed. Alternatives capable of meeting the requirements of industrial processes, in terms of productivity, cost-effectiveness and environmental issues (e.g., enantioselective membranes) are critically reviewed. The impact of combinatorial methodologies on faster and more effective development and optimisation of novel chiral selectors is outlined. Finally, the merits and Limitations of most recent trends in discrimination of enantiomers, including advances in the fields of sensors, microanalysis systems, chiroptical methods and chemical force microscopy are evaluated. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 33
页数:31
相关论文
共 263 条
[1]   Determination of absolute configuration using circular dichroism: Troger's base revisited using vibrational circular dichroism [J].
Aamouche, A ;
Devlin, FJ ;
Stephens, PJ .
CHEMICAL COMMUNICATIONS, 1999, (04) :361-362
[2]  
Aboul-Enein H.Y., 1997, IMPACT STEREOCHEMIST
[3]   DIRECT LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERS ON IMMOBILIZED PROTEIN STATIONARY PHASES .3. OPTICAL RESOLUTION OF A SERIES OF N-AROYL D,L-AMINO ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON BOVINE SERUM-ALBUMIN COVALENTLY BOUND TO SILICA [J].
ALLENMARK, S ;
BOMGREN, B ;
BOREN, H .
JOURNAL OF CHROMATOGRAPHY, 1983, 264 (01) :63-68
[4]  
Allenmark S. G., 1991, CHROMATOGRAPHIC ENAN
[5]   PROTEINS AND PEPTIDES AS CHIRAL SELECTORS IN LIQUID-CHROMATOGRAPHY [J].
ALLENMARK, SG ;
ANDERSSON, S .
JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) :167-179
[6]   A new class of network-polymeric chiral stationary phases [J].
Allenmark, SG ;
Andersson, S ;
Moller, P ;
Sanchez, D .
CHIRALITY, 1995, 7 (04) :248-256
[7]   ENANTIOMERIC RESOLUTION OF SULFOXIDES ON A DACH-DNB CHIRAL STATIONARY-PHASE - A QUANTITATIVE STRUCTURE-ENANTIOSELECTIVE RETENTION RELATIONSHIP (QSERR) STUDY [J].
ALTOMARE, C ;
CAROTTI, A ;
CELLAMARE, S ;
FANELLI, F ;
GASPARRINI, F ;
VILLANI, C ;
CARRUPT, PA ;
TESTA, B .
CHIRALITY, 1993, 5 (07) :527-537
[8]   A review of the current status of capillary electrochromatography technology and applications [J].
Altria, KD ;
Smith, NW ;
Turnbull, CH .
CHROMATOGRAPHIA, 1997, 46 (11-12) :664-674
[9]  
Altria KD, 1998, TRAC-TREND ANAL CHEM, V17, P214, DOI 10.1016/S0165-9936(98)00008-9
[10]  
[Anonymous], 1994, PRACTICAL APPROACH C, DOI DOI 10.1002/bit.20729