Electrodeposition of carbon nanotubes-chitosan-glucose oxidase biosensing composite films triggered by reduction of p-benzoquinone or H2O2

被引:94
作者
Qingmei Zhou [1 ]
Qingji Xie [1 ]
Yingchun Fu [1 ]
Zhaohong Su [1 ]
Xue'en Jia [1 ]
Shouzhuo Yao [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Key Lab Chem Biol & Tradit Chinese Med Res, Minist Educ China, Changsha 410081, Peoples R China
关键词
D O I
10.1021/jp073884i
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We report here on the electroreduction of p-benzoquinone (BQ) or H2O2 as a new trigger for simple, fast, uniform, and controllable electrodeposition of chitosan (CS) hydrogels and biosensing nanocomposite films of CS, multiwalled carbon nanotubes (MWCNTs), and glucose oxidase (GOD). The multiparameter electrochemical quartz crystal microbalance (EQCM) based on crystal electroacoustic impedance analysis was used to dynamically monitor the deposition processes. When the EQCM Au electrode was immersed in a weakly acidic solution (here pH 5.1 acetic buffer) containing BQ (or H2O2) and CS, the proton consumption during BQ (or H2O2) electroreduction increased the local solution pH near the electrode surface and led to the deposition of CS hydrogel on the electrode surface at local pH near and above the pK(a) value of CS. The concentration of BQ (or H2O2) required for CS electrodeposition was theoretically evaluated based on an electrogenerated base-to-acid titration model and supported by experiments. Co-deposition of GOD and MWCNTs with the CS hydrogel was achieved, and the resulting MWCNTs-CS-GOD nanocomposite films were demonstrated for glucose biosensing. The MWCNTs-CS-GOD enzyme electrode prepared by BQ reduction exhibited a current sensitivity of 6.7 mu A mM(-1) cm(-2) to glucose, and the linear range for glucose detection at 0.7 V vs SCE was from 5 mu M to 8 mM, with a detection limit of 2 mu M and a Michaelis-Menten constant of 6.8 mM. The BQ-electroreduction protocol exhibited the best sensor performance, as compared with H2O2-reduction and previously reported water-reduction values. The present protocol via electroreduction of a deliberately added oxidant that is accompanied
引用
收藏
页码:11276 / 11284
页数:9
相关论文
共 51 条
[1]   HYDROGEN-ION TITRATION OF CHITOSANS WITH VARYING DEGREES OF N-ACETYLATION BY MONITORING INDUCED H-1-NMR CHEMICAL-SHIFTS [J].
ANTHONSEN, MW ;
SMIDSROD, O .
CARBOHYDRATE POLYMERS, 1995, 26 (04) :303-305
[2]  
Buttry D., 1991, ELECTROANALYTICAL CH, V17
[3]  
Chen TH, 2000, BIOTECHNOL BIOENG, V70, P564, DOI 10.1002/1097-0290(20001205)70:5<564::AID-BIT11>3.0.CO
[4]  
2-W
[5]   Combinatorial screening for enzyme-mediated coupling. Tyrosinase-catalyzed coupling to create protein-chitosan conjugates [J].
Chen, TH ;
Vazquez-Duhalt, R ;
Wu, CF ;
Bentley, WE ;
Payne, GF .
BIOMACROMOLECULES, 2001, 2 (02) :456-462
[6]   Electrode coatings based on chitosan scaffolds [J].
Cruz, J ;
Kawasaki, M ;
Gorski, W .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :680-686
[7]   Glucose biosensor based on multi-walled carbon nanotube modified glassy carbon electrode [J].
Dai, YQ ;
Shiu, KK .
ELECTROANALYSIS, 2004, 16 (20) :1697-1703
[8]   New glucose biosensor based on a poly(o-phenylendiamine)/glucose oxidase-glutaraldehyde/Prussian blue/Au electrode with QCM monitoring of various electrode-surface modifications [J].
Deng, CY ;
Li, MR ;
Xie, QJ ;
Liu, ML ;
Tan, YM ;
Xu, XH ;
Yao, SZ .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :85-94
[9]   A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor [J].
Du, Ying ;
Luo, Xi-Liang ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOELECTROCHEMISTRY, 2007, 70 (02) :342-347
[10]   Electrochemically induced deposition of a polysaccharide hydrogel onto a patterned surface [J].
Fernandes, R ;
Wu, LQ ;
Chen, TH ;
Yi, HM ;
Rubloff, GW ;
Ghodssi, R ;
Bentley, WE ;
Payne, GF .
LANGMUIR, 2003, 19 (10) :4058-4062