Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading

被引:65
作者
Garcia, Santiago [1 ]
Kandar, Forum [1 ]
Boyle, Andrew [1 ]
Colvin-Adams, Monica [1 ]
Lliao, Kenneth [1 ]
Joyce, Lyle [1 ]
John, Ranjit [1 ]
机构
[1] Univ Minnesota, Div Cardiol, Dept Cardiol, Minneapolis, MN 55455 USA
关键词
D O I
10.1016/j.healun.2007.12.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In patients with end-stage heart failure, the use of left ventricular assist devices (LVADs) has improved clinical outcomes. Although newer continuous-flow devices have significant advantages, the effect of continuous flow on left ventricular unloading and hemodynamics is less well established. The aim of this investigation was to compare the effects of pulsatile- vs continuous-flow LVADs on left ventricular reverse remodeling and hemodynamic indices. Methods: Thirty-five patients undergoing implantation with a pulsatile volume displacement pump operating at fixed speed (n = 15; HeartMate XVE; Thoratec Corp., Pleasanton, CA) or a continuous-flow rotary pump with an axial design operating at a fixed rotor speed (n = 20; HeartMate II; Thoratec) were evaluated. Right heart catheterization and echocardiography were performed pre-operatively, and at 1- and 6-month follow-up intervals. Results: Thirty-five of 40 eligible patients with end-stage heart failure were included in this study. When used at fixed speed, use of both devices led to a substantial reduction in left ventricular volumes and dimensions at 1 month (p < 0.01). A marked and sustained reduction in filling pressures was also noted with both devices at 1 and 6 months (p < 0.01). The volume and pressure unloading effects of the HeartMate XVE were not superior to those with the HeartMate II (all p-values not statistically significant). Conclusions: Substantial left ventricular unloading and hemodynamic improvement is achieved with the HeartMate XVE and the HeartMate II. We conclude that continuous-flow LVADs are as effective as pulsatile-flow LVADs with regard to degree of left ventricular unloading and cardiac hemodynamics.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 20 条
  • [1] Altemose GT, 1997, J HEART LUNG TRANSPL, V16, P765
  • [2] Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support
    Amir, O
    Radovancevic, B
    Delgado, RM
    Kar, B
    Radovancevic, R
    Henderson, M
    Cohn, WE
    Smart, FW
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (04) : 391 - 394
  • [3] Bolno Paul B., 2003, Cardiology Clinics, V21, P15, DOI 10.1016/S0733-8651(03)00002-X
  • [4] Development of the Nimbus/University of Pittsburgh innovative ventricular assist system
    Butler, KC
    Dow, JJ
    Litwak, P
    Kormos, RL
    Borovetz, HS
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (02) : 790 - 794
  • [5] In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices
    DiGiorgi, PL
    Smith, DL
    Naka, Y
    Oz, MC
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (02) : 186 - 192
  • [6] Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    Frazier, OH
    Rose, EA
    Oz, MC
    Dembitsky, W
    McCarthy, P
    Radovancevic, B
    Poirier, VL
    Dasse, KA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (06) : 1186 - 1195
  • [7] IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM
    FRAZIER, OH
    ROSE, EA
    MCCARTHY, P
    BURTON, NA
    TECTOR, A
    LEVIN, H
    KAYNE, HL
    POIRIER, VL
    DASSE, KA
    [J]. ANNALS OF SURGERY, 1995, 222 (03) : 327 - 338
  • [8] HeartMate II left ventricular assist system: From concept to first clinical use
    Griffith, BP
    Kormos, RL
    Borovetz, HS
    Litwak, K
    Antaki, JF
    Poirier, VL
    Butler, KC
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03) : S116 - S120
  • [9] Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    Klotz, S
    Deng, MC
    Stypmann, J
    Roetker, J
    Wilhelm, MJ
    Hammel, D
    Scheld, HH
    Schmid, C
    [J]. ANNALS OF THORACIC SURGERY, 2004, 77 (01) : 143 - 149
  • [10] Use of a continuous-flow device in patients awaiting heart transplantation
    Miller, Leslie W.
    Pagani, Francis D.
    Russell, Stuart D.
    John, Ranjit
    Boyle, Andrew J.
    Aaronson, Keith D.
    Conte, John V.
    Naka, Yoshifumi
    Mancini, Donna
    Delgado, Reynolds M.
    MacGillivray, Thomas E.
    Farrar, David J.
    Frazier, O. H.