Background-The suggestion that increased QT dispersion (QTD) is due to increased differences in local action potential durations within the myocardium is wanting. An alternative explanation was sought by relating QTD to vectorcardiographic T-loop morphology. Methods and Results-The T loop is characterized by its amplitude and width (defined as the spatial angle between the mean vectors of the first and second halves of-the loop). We reasoned that small, wide ("pathological") T loops produce larger QTD than large, narrow ("normal") loops. To quantify the relationship between QTD and T-loop morphology, we used a program for automated analysis of ECGs and a database of 1220 standard simultaneous 12-lead ECGs. For each EGG, QT durations, QTD, and T-loop parameters were computed. T-loop amplitude and width were dichotomized, with 250 mu V (small versus large amplitudes) and 30 degrees (narrow versus wide loops) taken as thresholds. Over all 1220 ECGs, QTDs were smallest for large, narrow T loops (54.2 +/- 27.1 ms) and largest for small, wide loops (69.5 +/- 33.5 ms; P<0.001). Conclusions-QTD is an attribute of T-loop morphology, as expressed by T-loop amplitude and width.
引用
收藏
页码:1458 / 1463
页数:6
相关论文
共 35 条
[1]   CLINICAL RELEVANCE OF CARDIAC-ARRHYTHMIAS GENERATED BY AFTERDEPOLARIZATIONS - ROLE OF M-CELLS IN THE GENERATION OF U WAVES, TRIGGERED ACTIVITY AND TORSADE-DE-POINTES [J].
ANTZELEVITCH, C ;
SICOURI, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (01) :259-277
[2]  
Badilini F, 1997, ANN NONINVAS ELECTRO, V2, P146
[3]   QT DISPERSION AND SUDDEN UNEXPECTED DEATH IN CHRONIC HEART-FAILURE [J].
BARR, CS ;
NAAS, A ;
FREEMAN, M ;
LANG, CC ;
STRUTHERS, AD .
LANCET, 1994, 343 (8893) :327-329
[4]  
BARR RC, 1989, COMPREHENSIVE ELECTR, P129
[5]   THE ZERO OF POTENTIAL - A PERSISTENT ERROR [J].
BURGER, HC .
AMERICAN HEART JOURNAL, 1955, 49 (04) :581-586
[6]  
CHOU TC, 1967, CLIN VECTORCARDIOGRA
[7]  
CLARKSON PBM, 1995, QJM-MON J ASSOC PHYS, V88, P327
[8]  
COOKSEY JD, 1977, CLIN VECTOCARDIOGRAP, P128
[9]   IMPORTANCE OF LEAD SELECTION IN QT INTERVAL MEASUREMENT [J].
COWAN, JC ;
YUSOFF, K ;
MOORE, M ;
AMOS, PA ;
GOLD, AE ;
BOURKE, JP ;
TANSUPHASWADIKUL, S ;
CAMPBELL, RWF .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (01) :83-87
[10]  
Darbar D, 1996, BRIT MED J, V312, P874