High throughput baggage scanning employing x-ray diffraction for accurate explosives detection.

被引:9
作者
Green, MC [1 ]
Partain, LD [1 ]
机构
[1] Varian Med Syst, Mountain View, CA 94043 USA
来源
NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY | 2003年 / 5048卷
关键词
D O I
10.1117/12.484697
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray systems dominate the installed base of airport baggage scanning systems for explosives detection. The majority are conveyer systems with projection line scanners. These systems can achieve a high throughput but exhibit a high false positive rate and require significant operator involvement. Systems employing computed tomography (CT) are currently being installed at a rapid rate. These can provide good discrimination of levels of x-ray absorption coefficient and can largely circumvent superimposition effects. Nonetheless CT measures only x-ray absorption coefficient per voxel which does not provide a means of specific material identification resulting in many false positives, and it is relatively straightforward to configure explosive materials so that they are undetectable by CT systems. Diffraction-based x-ray systems present a solution to this problem. They detect and measure atomic layer spacings in crystalline and microcrystalline materials with high sensitivity. This provides a means of specific material identification. The majority of explosive compounds are well crystallized solids at room temperature. X-ray diffraction systems using both conventional wavelength-dispersive diffraction and fixed-angle, multi-wavelength diffraction for improved throughput are described. Large-area, flat-panel x-ray detector technology coupled with an extended x-ray source will permit a full 3D volumetric x-ray diffraction scan of a bag in a single pass, (patent pending).
引用
收藏
页码:63 / 72
页数:10
相关论文
共 8 条
[1]  
BOMSDORF H, 1999, NDT NET, V4
[2]  
FEDEROFF BT, ENCY EXPLOSIVES RELA
[3]  
GALLANT G, 2002, GORD RES C ILL SUBST
[4]   ENERGY-DISPERSIVE X-RAY-DIFFRACTION TOMOGRAPHY [J].
HARDING, G ;
NEWTON, M ;
KOSANETZKY, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :33-41
[5]  
Strecker H., 1998, MEDICAMUNDI, V42, P30
[6]   Comparison of PbI2 and HgI2 for direct detection active matrix x-ray image sensors [J].
Street, RA ;
Ready, SE ;
Van Schuylenbergh, K ;
Ho, J ;
Boyce, JB ;
Nylen, P ;
Shah, K ;
Melekhov, L ;
Hermon, H .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (05) :3345-3355
[7]  
ZENTAI G, 2003, SPIE PHYS MED IM C S
[8]  
2002, AIRPORT REPORT, V12, P2